FireCADCalc

Intercooled Gas Turbine Cycle: Compressor Work and Efficiency

Compressor work, net specific work and efficiency of a gas turbine with two equal-ratio compression stages and an intercooler, against single-stage.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative ratio 8, intercooled to 300 KHigh ratio 30 aero-derivativeLow ratio 4

Accepted: -43.15 to 56.85 °C
Accepted: 1.5 to 50
Accepted: 526.85 to 1,726.8 °C
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 0.95 to 1.25 kJ/(kg·K)
Accepted: 1.25 to 1.41
Accepted: -43.15 to 126.85 °C

Results

Two stages at √r_p each with cooling to T_ic between them: compressing cooler air takes less work, raising specific work substantially. Efficiency rises only at high pressure ratios or with a recuperator, because the combustor must now heat the air from a lower T₂. Aero-derivative units such as the LMS100 use intercooling for output.

Compressor work, single stage499.10kJ/kg
Compressor work, intercooled406.90kJ/kg
Net specific work, intercooled550.63kJ/kg
Efficiency, intercooled42.141%
Efficiency, single stage44.243%
Compressor delivery, intercooled213.79°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative ratio 8, intercooled to 300 K. The inputs, in the units selected above:

InputValue
Compressor inlet temperature15.000 °C
Overall pressure ratio8.0000 -
Turbine inlet temperature1,100.0 °C
Compressor isentropic efficiency85.000 %
Turbine isentropic efficiency88.000 %
Mean specific heat1.1000 kJ/(kg·K)
Heat capacity ratio1.3600 -
Air temperature after the intercooler26.850 °C

Applying the formula below gives:

ResultValue
Compressor work, single stage273.71 kJ/kg
Compressor work, intercooled241.14 kJ/kg
Net specific work, intercooled321.52 kJ/kg
Efficiency, intercooled30.404 %
Efficiency, single stage31.414 %
Compressor delivery, intercooled138.67 °C

Open this example in the calculator and change any input.

Formula

\(w_{c,ic} = c_p\left[T_1\frac{r_p^{k/2} - 1}{\eta_c} + T_{ic}\frac{r_p^{k/2} - 1}{\eta_c}\right], \quad k = \frac{\gamma - 1}{\gamma}\)

Variables

Symbol Meaning SI unit
\(T_1\) Compressor inlet temperature K
\(r_p\) Overall pressure ratio -
\(T_3\) Turbine inlet temperature K
\(\eta_c\) Compressor isentropic efficiency -
\(\eta_t\) Turbine isentropic efficiency -
\(c_p\) Mean specific heat J/(kg·K)
\(\gamma\) Heat capacity ratio -
\(T_{ic}\) Air temperature after the intercooler K
\(w_{c,1}\) Compressor work, single stage J/kg
\(w_{c,ic}\) Compressor work, intercooled J/kg
\(w_{net}\) Net specific work, intercooled J/kg
\(\eta\) Efficiency, intercooled -
\(\eta_0\) Efficiency, single stage -
\(T_2\) Compressor delivery, intercooled K

Method and standards

Intercooled cycle.

Where it is used

  • Peaking and aero-derivative unit studies.
  • Compressed air and process compressor trains.

Common mistakes

  • Expecting large efficiency gains at low pressure ratio.
  • Ignoring intercooler pressure loss.

Assumptions and limits

  • Constant c_p and γ; equal stage ratios; no pressure losses.

References

  • Air-standard cycle with intercooling

Questions and answers

Why does intercooling not always raise efficiency?

It lowers compressor work but also compressor delivery temperature, so the combustor must add more heat; efficiency gains need high ratios or recuperation.

Why split the pressure ratio equally?

Equal ratios with cooling back to inlet temperature minimise total compressor work.

What do the defaults represent?

An illustrative cycle at pressure ratio 8 with intercooling to 300 K between two equal stages.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers, Cohen and Straznicky, Gas Turbine Theory, 6th ed. (Pearson, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.