Worked example
Example: Ratio 20, 1,450 K and 1,400 K, 30 C day. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Compressor pressure ratio | 20.000 - |
| Compressor polytropic efficiency | 88.000 % |
| Turbine polytropic efficiency (both turbines) | 87.000 % |
| HP turbine inlet temperature | 1,176.8 °C |
| LP turbine inlet temperature (after reheat) | 1,126.8 °C |
| First combustor pressure loss | 3.0000 % |
| Reheat combustor pressure loss | 4.0000 % |
| Ambient (compressor inlet) pressure | 1.0130 bar |
| Ambient temperature | 29.850 °C |
| Turbine exhaust pressure | 1.0400 bar |
| HP turbine pressure ratio (sets the reheat pressure) | 3.5000 - |
| Mechanical efficiency | 98.500 % |
| Combustion efficiency | 99.500 % |
| Air specific heat | 1.0050 kJ/(kg·K) |
| Air ratio of specific heats | 1.4000 - |
| Gas specific heat | 1.1480 kJ/(kg·K) |
| Gas ratio of specific heats | 1.3333 - |
| Fuel net calorific value | 43,100 kJ/kg |
| Fuel H/C atom ratio (kerosene about 1.92, methane 4) | 1.9200 - |
| Power required (for the air flow) | 240.00 MW |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compressor delivery temperature | 801.41 K |
| Compressor work per kg air | 500.90 kJ/kg |
| HP turbine inlet pressure | 19.652 bar |
| Reheat pressure (HP turbine exit) | 5.6149 bar |
| HP turbine exit temperature | 1,104.2 K |
| LP turbine inlet pressure | 5.3903 bar |
| LP turbine pressure ratio | 5.1830 |
| Equal-split HP ratio (ignoring the reheat loss) | 4.3470 |
| Exhaust temperature (EGT) | 978.83 K |
| Net specific work | 366.42 kJ/kg |
| Total fuel/air ratio | 0.027742 |
| Specific fuel consumption | 0.27257 kg/kWh |
| Cycle efficiency (LHV) | 30.644 % |
| Air flow for the power required | 654.99 kg/s |
Open this example in the calculator and change any input.
Formula
\(\frac{T_{02}}{T_{01}} = r_c^{(\gamma_a-1)/(\gamma_a\eta_{\infty c})}, \quad \frac{T_{03}}{T_{04}} = \left(\frac{p_{03}}{p_{04}}\right)^{\eta_{\infty t}(\gamma_g-1)/\gamma_g}\)
\(W = \eta_m c_{pg}\left[(T_{03} - T_{04}) + (T_{05} - T_{06})\right] - c_{pa}(T_{02} - T_{01}), \quad \eta = \frac{W}{fQ_{net}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(r_c\) | Compressor pressure ratio | - |
| \(\eta_{\infty c}\) | Compressor polytropic efficiency | - |
| \(\eta_{\infty t}\) | Turbine polytropic efficiency (both turbines) | - |
| \(T_{03}\) | HP turbine inlet temperature | K |
| \(T_{05}\) | LP turbine inlet temperature (after reheat) | K |
| \(\Delta p/p_{02}\) | First combustor pressure loss | - |
| \(\Delta p/p_{04}\) | Reheat combustor pressure loss | - |
| \(p_a\) | Ambient (compressor inlet) pressure | Pa |
| \(T_a\) | Ambient temperature | K |
| \(p_{06}\) | Turbine exhaust pressure | Pa |
| \(p_{03}/p_{04}\) | HP turbine pressure ratio (sets the reheat pressure) | - |
| \(\eta_m\) | Mechanical efficiency | - |
| \(\eta_b\) | Combustion efficiency | - |
| \(c_{pa}\) | Air specific heat | J/(kg·K) |
| \(\gamma_a\) | Air ratio of specific heats | - |
| \(c_{pg}\) | Gas specific heat | J/(kg·K) |
| \(\gamma_g\) | Gas ratio of specific heats | - |
| \(Q_{net}\) | Fuel net calorific value | J/kg |
| \(y\) | Fuel H/C atom ratio (kerosene about 1.92, methane 4) | - |
| \(P\) | Power required (for the air flow) | W |
| \(T_{02}\) | Compressor delivery temperature | K |
| \(W_c\) | Compressor work per kg air | J/kg |
| \(p_{03}\) | HP turbine inlet pressure | Pa |
| \(p_{04}\) | Reheat pressure (HP turbine exit) | Pa |
| \(T_{04}\) | HP turbine exit temperature | K |
| \(p_{05}\) | LP turbine inlet pressure | Pa |
| \(p_{05}/p_{06}\) | LP turbine pressure ratio | - |
| \(\sqrt{p_{03}/p_{06}}\) | Equal-split HP ratio (ignoring the reheat loss) | - |
| \(T_{06}\) | Exhaust temperature (EGT) | K |
| \(W\) | Net specific work | J/kg |
| \(f\) | Total fuel/air ratio | - |
| \(SFC\) | Specific fuel consumption | kg/J |
| \(\eta\) | Cycle efficiency (LHV) | - |
| \(\dot m\) | Air flow for the power required | kg/s |
Method and standards
Textbook reheat cycle with polytropic efficiencies and enthalpy-balance fuel/air ratios.
Where it is used
- Choosing the reheat pressure for a sequential-combustion gas turbine in a combined cycle.
- Comparing reheat with simple and intercooled cycles.
Common mistakes
- Splitting the turbine ratios equally when the exhaust heat is to be used.
- Forgetting the second combustor's pressure loss.
Assumptions and limits
- Constant flow; no cooling air; constant c_p and γ.
Questions and answers
Why not always use equal turbine pressure ratios?
Equal ratios give the most specific work, but the exhaust is then very hot. For a combined cycle a higher reheat pressure brings the exhaust to about 600 °C and raises the gas turbine efficiency, at about 10 % less specific work.
What do the defaults represent?
An illustrative case: Ratio 20, 1,450 K and 1,400 K, 30 C day. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 2.3, Example 2.3 and Fig. 2.23; NIST Chemistry WebBook Shomate data for the fuel/air ratios