FireCADCalc

Steam Pipe Sizing by Velocity

Inside diameter of a steam pipe for a mass flow and design velocity, with the steam's specific volume from IAPWS-IF97 and the velocity in a chosen pipe.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 10 t/h saturated steam at 10.5 bar(a), 25 m/s, check DN150 (154.1 mm)50 t/h at 66 bar(a) / 485 °C, 40 m/s2 t/h saturated at 4 bar(a), 20 m/s, check DN100 (102.3 mm)

Absolute; choose a gauge unit to enter gauge readings.
From your piping specification; the calculator does not suggest one.

Results

Inside diameter for the design velocity148.72mm
Volume flow of steam2,501.3m³/h
Specific volume of the steam0.050026m³/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h saturated steam at 10.5 bar(a), 25 m/s, check DN150 (154.1 mm). The inputs, in the units selected above:

InputValue
Steam flow10,000 kg/h
Steam pressure (absolute)10.500 bar
Steam conditionDry saturated
Steam temperature (superheated only)250.00 °C
Design velocity25.000 m/s
Chosen pipe inside diameter to check (0 = skip)154.10 mm

Applying the formula below gives:

ResultValue
Inside diameter for the design velocity162.00 mm
Velocity in the chosen pipe27.628 m/s
Volume flow of steam1,855.0 m³/h
Specific volume of the steam0.18550 m³/kg

Open this example in the calculator and change any input.

Formula

\(\dot V = \dot m\,v \qquad D = \sqrt{\frac{4\,\dot V}{\pi\,u}} \qquad u_{sel} = \frac{4\,\dot V}{\pi\,D_{sel}^2}\)

Variables

Symbol Meaning SI unit
\(\dot m\) steam flow kg/s
\(p\) steam pressure, absolute Pa
\(\text{state}\) dry saturated or superheated steam –
\(T_s\) steam temperature (superheated) K
\(u\) design velocity m/s
\(D_{sel}\) chosen pipe inside diameter m
\(D\) inside diameter for the design velocity m
\(u_{sel}\) velocity in the chosen pipe m/s
\(\dot V\) volume flow of steam m³/s
\(v\) specific volume of the steam m³/kg

Method and standards

Continuity for a full circular pipe, with the specific volume from FireCAD's IAPWS-IF97 implementation.

Where it is used

  • Sizing steam mains and branches in boiler houses and process plants.
  • Checking existing lines for a capacity increase.
  • Sizing PRDS inlet and outlet lines.

Common mistakes

  • Using the same velocity for saturated and superheated steam.
  • Sizing on velocity alone when pressure drop limits a long line.
  • Using gauge pressure for steam density.

Assumptions and limits

  • Sizing by velocity only; check the pressure drop with the steam pipe pressure drop calculator.
  • Inside diameter: outside diameter minus twice the wall thickness.
  • Dry steam; wet steam needs separators and drainage.

References

  • IAPWS R7-97(2012) IF97 (specific volume)
  • Continuity equation

Questions and answers

How do I size a steam pipe?

Volume flow = mass flow × specific volume; area = volume flow ÷ velocity. 10 t/h of dry saturated steam at 10.5 bar(a) is 0.515 m³/s; at 25 m/s it needs a 162 mm bore, so a DN150 pipe (154.1 mm) runs at 27.6 m/s.

Which velocity should I use?

The one in your piping specification; it balances pipe cost against pressure drop, noise and erosion. The calculator does not suggest one.

Why does low-pressure steam need bigger pipes?

Its specific volume is larger: 0.46 m³/kg at 4 bar(a) against 0.19 m³/kg at 10.5 bar(a).

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.