FireCADCalc

Pipe Thermal Expansion and Offset Leg

Thermal expansion of a pipe run between cold and hot temperatures, and the length of offset leg that absorbs it by the guided-cantilever method.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserBoiler

Inputs

Examples: Steam main 100 m, 20 to 184 °C, carbon steel, DN150HP line 60 m, 20 to 485 °C, alloy steel, DN200Feedwater 40 m, 25 to 150 °C, DN80

Mean value between the two temperatures from your piping code's expansion table (ASME B31.1 Appendix B). Carbon steel is about 12–14 µm/(m·K), austenitic stainless about 17–18.
Carbon steel about 200 000 MPa cold; your code may ask for the cold or the hot value.
From your piping code for the material and temperatures (ASME B31.1 §102.3.2). Enter the code value.

Results

Thermal expansion of the run206.64mm
Offset leg to absorb it (guided cantilever)11.794m
Expansion per unit length0.002066

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steam main 100 m, 20 to 184 °C, carbon steel, DN150. The inputs, in the units selected above:

InputValue
Length of the pipe run100.00 m
Mean coefficient of linear expansion12.600 µm/(m·K)
Installation (cold) temperature20.000 °C
Operating (hot) temperature184.00 °C
Pipe outside diameter (for the leg)168.30 mm
Modulus of elasticity200,000 MPa
Allowable expansion stress range150.00 MPa

Applying the formula below gives:

ResultValue
Thermal expansion of the run206.64 mm
Offset leg to absorb it (guided cantilever)11.794 m
Expansion per unit length0.002066

Open this example in the calculator and change any input.

Formula

\(\Delta L = \alpha\,L\,(T_h - T_c) \qquad L_o = \sqrt{\frac{3\,E\,D_o\,\Delta L}{S_A}}\)

Variables

Symbol Meaning SI unit
\(L\) length of the pipe run m
\(\alpha\) mean coefficient of linear expansion 1/K
\(T_c\) installation (cold) temperature K
\(T_h\) operating (hot) temperature K
\(D_o\) pipe outside diameter m
\(E\) modulus of elasticity Pa
\(S_A\) allowable expansion stress range Pa
\(\Delta L\) thermal expansion of the run m
\(L_o\) offset leg to absorb it m
\(\Delta L / L\) expansion per unit length –

Method and standards

Linear thermal expansion with a mean coefficient between the two temperatures, taken from the expansion table of your piping code (ASME B31.1 Appendix B). The offset leg follows the guided-cantilever method of M.W. Kellogg (Design of Piping Systems): a leg fixed at both ends, bent by a lateral movement ΔL, has a bending stress 3·E·D·ΔL/L².

Where it is used

  • Designing loops, bends and expansion joints for steam and hot water lines.
  • Checking anchor and guide locations.
  • Estimating movement at equipment nozzles.

Common mistakes

  • Using the operating temperature without the installation temperature.
  • Forgetting that anchors must carry the thrust.
  • Using one expansion coefficient for all materials.

Assumptions and limits

  • The guided-cantilever method is conservative and ignores the flexibility of bends and of the run itself.
  • Stress intensification at fittings, sustained loads and anchor forces are not checked.
  • Allowable stress range and modulus are your code values.
  • A cold service (T_h below T_c) gives a negative ΔL (contraction); the leg uses the magnitude |ΔL|.

References

  • ASME B31.1 Appendix B (expansion data, input)
  • Guided-cantilever method (M.W. Kellogg, Design of Piping Systems)

Questions and answers

How much does a steam pipe expand?

ΔL = α·L·ΔT. 100 m of carbon steel pipe heated from 20 °C to 184 °C (10 bar g steam) with α = 12.6 µm/(m·K) grows 207 mm.

How long must the offset leg be?

By the guided-cantilever method L = √(3·E·D·ΔL/S). For that expansion on a DN150 pipe with E = 200 000 MPa and an allowable stress range of 150 MPa the leg is about 11.8 m, which is why long runs are split by anchors and loops.

Is this a stress analysis?

No. It is a first estimate for layout. Critical and hot lines need a flexibility analysis to your piping code.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.