Worked example
Example: Steam main 100 m, 20 to 184 °C, carbon steel, DN150. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Length of the pipe run | 100.00 m |
| Mean coefficient of linear expansion | 12.600 µm/(m·K) |
| Installation (cold) temperature | 20.000 °C |
| Operating (hot) temperature | 184.00 °C |
| Pipe outside diameter (for the leg) | 168.30 mm |
| Modulus of elasticity | 200,000 MPa |
| Allowable expansion stress range | 150.00 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thermal expansion of the run | 206.64 mm |
| Offset leg to absorb it (guided cantilever) | 11.794 m |
| Expansion per unit length | 0.002066 |
Open this example in the calculator and change any input.
Formula
\(\Delta L = \alpha\,L\,(T_h - T_c) \qquad L_o = \sqrt{\frac{3\,E\,D_o\,\Delta L}{S_A}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | length of the pipe run | m |
| \(\alpha\) | mean coefficient of linear expansion | 1/K |
| \(T_c\) | installation (cold) temperature | K |
| \(T_h\) | operating (hot) temperature | K |
| \(D_o\) | pipe outside diameter | m |
| \(E\) | modulus of elasticity | Pa |
| \(S_A\) | allowable expansion stress range | Pa |
| \(\Delta L\) | thermal expansion of the run | m |
| \(L_o\) | offset leg to absorb it | m |
| \(\Delta L / L\) | expansion per unit length | – |
Method and standards
Linear thermal expansion with a mean coefficient between the two temperatures, taken from the expansion table of your piping code (ASME B31.1 Appendix B). The offset leg follows the guided-cantilever method of M.W. Kellogg (Design of Piping Systems): a leg fixed at both ends, bent by a lateral movement ΔL, has a bending stress 3·E·D·ΔL/L².
Where it is used
- Designing loops, bends and expansion joints for steam and hot water lines.
- Checking anchor and guide locations.
- Estimating movement at equipment nozzles.
Common mistakes
- Using the operating temperature without the installation temperature.
- Forgetting that anchors must carry the thrust.
- Using one expansion coefficient for all materials.
Assumptions and limits
- The guided-cantilever method is conservative and ignores the flexibility of bends and of the run itself.
- Stress intensification at fittings, sustained loads and anchor forces are not checked.
- Allowable stress range and modulus are your code values.
- A cold service (T_h below T_c) gives a negative ΔL (contraction); the leg uses the magnitude |ΔL|.
References
- ASME B31.1 Appendix B (expansion data, input)
- Guided-cantilever method (M.W. Kellogg, Design of Piping Systems)
Questions and answers
How much does a steam pipe expand?
ΔL = α·L·ΔT. 100 m of carbon steel pipe heated from 20 °C to 184 °C (10 bar g steam) with α = 12.6 µm/(m·K) grows 207 mm.
How long must the offset leg be?
By the guided-cantilever method L = √(3·E·D·ΔL/S). For that expansion on a DN150 pipe with E = 200 000 MPa and an allowable stress range of 150 MPa the leg is about 11.8 m, which is why long runs are split by anchors and loops.
Is this a stress analysis?
No. It is a first estimate for layout. Critical and hot lines need a flexibility analysis to your piping code.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.