FireCADCalc

Weight of Pipe Filled with Water and Insulated

Weight per metre of a steel pipe, its contents and insulation with cladding, and the total for a length, for support and hanger loads.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 6-inch Sch 40 full of water, 50 mm insulation2-inch Sch 80 steam line, empty, 40 mm12-inch Std water main, no insulation

Results

Results are masses per metre; the weight (force) per metre is w g = 95.5 N/m, for support loads and span checks.

Pipe7.4816kg/m
Contents0kg/m
Insulation1.2604kg/m
Total per metre9.7420kg/m
Total for the length58.452kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6-inch Sch 40 full of water, 50 mm insulation. The inputs, in the units selected above:

InputValue
Pipe outside diameter168.30 mm
Wall thickness7.1100 mm
Pipe material density7,850.0 kg/m³
Contents density (0 if empty or gas)998.00 kg/m³
Insulation thickness50.000 mm
Insulation density120.00 kg/m³
Cladding weight per metre2.0000 kg/m
Length (for the total)6.0000 m

Applying the formula below gives:

ResultValue
Pipe28.264 kg/m
Contents18.609 kg/m
Insulation4.1149 kg/m
Total per metre52.987 kg/m
Total for the length317.92 kg

Open this example in the calculator and change any input.

Formula

\(w_p = \rho_s \frac{\pi (D_o^2 - D_i^2)}{4}, \quad w_f = \rho_f \frac{\pi D_i^2}{4}, \quad w_i = \rho_i \frac{\pi \left[(D_o + 2t_i)^2 - D_o^2\right]}{4}\)

Variables

Symbol Meaning SI unit
\(D_o\) Pipe outside diameter m
\(t\) Wall thickness m
\(\rho_s\) Pipe material density kg/m³
\(\rho_f\) Contents density (0 if empty or gas) kg/m³
\(t_i\) Insulation thickness m
\(\rho_i\) Insulation density kg/m³
\(w_c\) Cladding weight per metre kg/m
\(L\) Length (for the total) m
\(w_p\) Pipe kg/m
\(w_f\) Contents kg/m
\(w_i\) Insulation kg/m
\(w\) Total per metre kg/m
\(m\) Total for the length kg

Method and standards

Areas times densities.

Where it is used

  • Support and hanger design.
  • Pipe rack loads.

Common mistakes

  • Forgetting test water.
  • Nominal instead of actual OD.

Assumptions and limits

  • Straight pipe.
  • Outputs are mass per metre (kg/m); multiply by g = 9.806 65 m/s² for the weight in N/m (given in a note).

References

  • Mass of annular sections

Questions and answers

6-inch Sch 40 pipe full of water with 50 mm insulation?

About 53 kg per metre.

Why include water for steam lines?

Hydrotest and lines that flood on start-up must be supported full.

What about valves?

Add them as point loads.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.