FireCADCalc

Pipe Expansion Loop Leg Length (Guided Cantilever)

Thermal growth of a pipe run and the leg length of an expansion loop, L-bend or Z-bend needed to absorb it, by the guided cantilever method.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserBoiler

Inputs

Examples: DN150, 60 m run, carbon steel 12 µm/m·K, 200 K riseDN100, 100 m, 12.5 µm/m·K, 150 KDN50 stainless, 40 m, 17 µm/m·K, 120 K

Take it from the piping code you work to.

Results

Guided cantilever: a quick, usually conservative check that ignores bend flexibility and assumes the leg ends stay parallel. A flexibility analysis decides for critical lines.

Thermal growth of the run144.00mm
Leg length to take all the growth (L-bend or Z-bend)9.8459m
Length of each of the two legs of a U-loop at mid-run6.9621m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: DN150, 60 m run, carbon steel 12 µm/m·K, 200 K rise. The inputs, in the units selected above:

InputValue
Pipe outside diameter168.30 mm
Straight run between anchors60.000 m
Mean coefficient of thermal expansion12.000 µm/(m·K)
Temperature change from installation200.00 K
Modulus of elasticity200.00 GPa
Allowed displacement stress range (your design value)150.00 MPa

Applying the formula below gives:

ResultValue
Thermal growth of the run144.00 mm
Leg length to take all the growth (L-bend or Z-bend)9.8459 m
Length of each of the two legs of a U-loop at mid-run6.9621 m

Open this example in the calculator and change any input.

Formula

\(\Delta = \alpha\, \Delta T\, L_r\)

\(L = \sqrt{\frac{3 E D_o \Delta}{S_A}}, \quad L_{loop} = \sqrt{\frac{3 E D_o (\Delta/2)}{S_A}}\)

Variables

Symbol Meaning SI unit
\(D_o\) Pipe outside diameter m
\(L_r\) Straight run between anchors m
\(\alpha\) Mean coefficient of thermal expansion 1/K
\(\Delta T\) Temperature change from installation K
\(E\) Modulus of elasticity Pa
\(S_A\) Allowed displacement stress range (your design value) Pa
\(\Delta\) Thermal growth of the run m
\(L\) Leg length to take all the growth (L-bend or Z-bend) m
\(L_{loop}\) Length of each of the two legs of a U-loop at mid-run m

Method and standards

The guided cantilever method treats each leg perpendicular to the growth as a beam fixed against rotation at both ends; the bending stress for the imposed deflection must stay within the allowed displacement stress range.

Where it is used

  • Laying out steam, condensate and hot water mains.
  • Checking whether an L-bend can absorb growth instead of a bellows.
  • Locating anchors and guides.

Common mistakes

  • Using the hot temperature instead of the change from installation.
  • Leaving guides too close to the loop.
  • Ignoring cold pull or pre-spring when it is used.

Assumptions and limits

  • Guided cantilever; bend flexibility ignored (conservative).
  • Allowed stress range from your code.
  • The U-loop result is the length of each leg only; the loop width (the run between the legs) and stress intensification at the bends are not considered.

References

  • Guided cantilever method (M.W. Kellogg, Design of Piping Systems)

Questions and answers

What loop does a 60 m DN150 steam line need for 200 K?

It grows 144 mm. One leg taking all of it needs 9.8 m; a U-loop at mid-run with two legs of 7.0 m shares it.

Where does the formula come from?

A leg held parallel at both ends bends like a guided cantilever: Δ = S L²/(3 E D), so L = √(3 E D Δ / S).

Is this enough for design?

For utility lines it is a common quick check; critical lines need a flexibility analysis to your piping code.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.