FireCADCalc

Sling Leg Tension and Angle Factor

Tension in each leg of a two-, three- or four-leg sling for a load and sling angle, with the angle factor and the minimum working load limit needed per leg.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 5 t, two legs at 60°10 t, four legs counted as three, 45°

Results

Lifting regulations and sling makers' tables govern; they count fewer legs as sharing the load for three- and four-leg slings. The WLL output is the leg tension expressed as a mass: choose a sling whose rated WLL (which already includes the maker's safety factor) is at least this; add any dynamic or uncertainty allowance your rules require.

Angle factor1.4142
Tension per leg46.229kN
Least rated working load limit per leg (leg tension as mass)4,714.0kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 t, two legs at 60°. The inputs, in the units selected above:

InputValue
Load mass5,000.0 kg
Legs sharing the load2 (also a three-leg sling, counted as 2 for safety)
Leg angle from horizontal60.000 °

Applying the formula below gives:

ResultValue
Angle factor1.1547
Tension per leg28.309 kN
Least rated working load limit per leg (leg tension as mass)2,886.8 kg

Open this example in the calculator and change any input.

Formula

\(T = \frac{Wg}{n\sin\theta}, \quad WLL = \frac{T}{g}\)

Variables

Symbol Meaning SI unit
\(W\) Load mass kg
\(n\) Legs sharing the load -
\(\theta\) Leg angle from horizontal rad
\(1/\sin\theta\) Angle factor -
\(T\) Tension per leg N
\(WLL\) Least rated working load limit per leg (leg tension as mass) kg
\(g\) Standard gravity, 9.806 65 m/s²

Method and standards

Equilibrium of forces.

Where it is used

  • Rigging plans.
  • Choosing sling size.

Common mistakes

  • Measuring the angle from vertical instead of horizontal.
  • Counting all four legs.

Assumptions and limits

  • Symmetrical lift; centre of gravity below the hook.
  • WLL is the leg tension as a mass with no extra design factor: a sling's rated WLL already includes the maker's safety factor, so pick one rated at least this; dynamic allowances are extra.

References

  • Statics of a symmetrical sling (definitions)

Questions and answers

Why do flat slings carry more?

Each leg must hold the vertical share of the load; as the angle flattens, the horizontal pull rises. At 30° each leg carries the full load.

Why count fewer legs?

Unequal leg lengths mean one or two legs may carry most of the load.

What do the defaults represent?

A 5 t load on a two-leg sling at 60° from horizontal.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.