FireCADCalc

Sound Level at a Distance (Point and Line Sources)

Sound pressure level at a new distance from a point or line source by the inverse-square law, and the level from a sound power level in a free field.

Thermal power plantProcess steam and utilities

Inputs

Examples: 90 dB at 1 m to 10 m, point; 100 dB power on a floorPipe line source 85 dB at 2 m to 16 mCompressor 95 dB at 1 m to 50 m; 105 dB power, wall corner

Results

Free-field spreading only; air absorption, barriers and room reflections are not included. L_p uses only L_W, Q and r₂; it is independent of L₁ and r₁. A line source of finite length l behaves as a point source beyond about l/π.

Level at the new distance (dB)61.021
Change in level (dB)-33.979
Level at r₂ from the sound power L_W (dB; independent of L₁ and r₁)66.049

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 90 dB at 1 m to 10 m, point; 100 dB power on a floor. The inputs, in the units selected above:

InputValue
Sound pressure level at the first distance (dB)90.000 -
First distance1.0000 m
New distance10.000 m
SourcePoint source (−6 dB per doubling)
Sound power level of a point source (dB)100.00 -
Directivity factor (1 free field, 2 on a floor, 4 at a wall edge)2.0000 -

Applying the formula below gives:

ResultValue
Level at the new distance (dB)70.000
Change in level (dB)-20.000
Level at r₂ from the sound power L_W (dB; independent of L₁ and r₁)72.018

Open this example in the calculator and change any input.

Formula

\(L_2 = L_1 - 20\log_{10}\frac{r_2}{r_1}\ (\text{point}), \quad L_2 = L_1 - 10\log_{10}\frac{r_2}{r_1}\ (\text{line})\)

\(L_p = L_W + 10\log_{10}\frac{Q}{4\pi r^2}\)

Variables

Symbol Meaning SI unit
\(L_1\) Sound pressure level at the first distance (dB) -
\(r_1\) First distance m
\(r_2\) New distance m
\(\text{source}\) Source -
\(L_W\) Sound power level of a point source (dB) -
\(Q\) Directivity factor (1 free field, 2 on a floor, 4 at a wall edge) -
\(L_2\) Level at the new distance (dB) -
\(\Delta L\) Change in level (dB) -
\(L_p\) Level at r₂ from the sound power L_W (dB; independent of L₁ and r₁) -
\(r\) Distance used for L_p, equal to r₂ m

Method and standards

Spherical and cylindrical spreading.

Where it is used

  • Noise at the boundary of a plant.
  • Siting compressors and DG sets.

Common mistakes

  • Using the line rule for machines.
  • Ignoring reflections indoors.

Assumptions and limits

  • Free field.
  • The two results are independent: L₂ comes from L₁ at r₁; L_p comes from the sound power L_W and directivity Q at r₂.
  • The line rule (10 log) holds for a long line close to it. A pipe or road of finite length l behaves as a point source (20 log) beyond about l/π; the page does not check distance against source length.

References

  • Geometric spreading: point source 20 log
  • line source 10 log; L_p = L_W + 10 log(Q / 4πr²)

Questions and answers

90 dB at 1 m: what at 10 m?

70 dB from a point source; 80 dB from a line source.

What does a 100 dB sound power source give at 10 m on a floor?

72.0 dB.

Why does it fail indoors?

Reflections keep the level up far from the source.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.