Worked example
Example: 90 dB at 1 m to 10 m, point; 100 dB power on a floor. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Sound pressure level at the first distance (dB) | 90.000 - |
| First distance | 1.0000 m |
| New distance | 10.000 m |
| Source | Point source (−6 dB per doubling) |
| Sound power level of a point source (dB) | 100.00 - |
| Directivity factor (1 free field, 2 on a floor, 4 at a wall edge) | 2.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Level at the new distance (dB) | 70.000 |
| Change in level (dB) | -20.000 |
| Level at r₂ from the sound power L_W (dB; independent of L₁ and r₁) | 72.018 |
Open this example in the calculator and change any input.
Formula
\(L_2 = L_1 - 20\log_{10}\frac{r_2}{r_1}\ (\text{point}), \quad L_2 = L_1 - 10\log_{10}\frac{r_2}{r_1}\ (\text{line})\)
\(L_p = L_W + 10\log_{10}\frac{Q}{4\pi r^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_1\) | Sound pressure level at the first distance (dB) | - |
| \(r_1\) | First distance | m |
| \(r_2\) | New distance | m |
| \(\text{source}\) | Source | - |
| \(L_W\) | Sound power level of a point source (dB) | - |
| \(Q\) | Directivity factor (1 free field, 2 on a floor, 4 at a wall edge) | - |
| \(L_2\) | Level at the new distance (dB) | - |
| \(\Delta L\) | Change in level (dB) | - |
| \(L_p\) | Level at r₂ from the sound power L_W (dB; independent of L₁ and r₁) | - |
| \(r\) | Distance used for L_p, equal to r₂ | m |
Method and standards
Spherical and cylindrical spreading.
Where it is used
- Noise at the boundary of a plant.
- Siting compressors and DG sets.
Common mistakes
- Using the line rule for machines.
- Ignoring reflections indoors.
Assumptions and limits
- Free field.
- The two results are independent: L₂ comes from L₁ at r₁; L_p comes from the sound power L_W and directivity Q at r₂.
- The line rule (10 log) holds for a long line close to it. A pipe or road of finite length l behaves as a point source (20 log) beyond about l/π; the page does not check distance against source length.
References
- Geometric spreading: point source 20 log
- line source 10 log; L_p = L_W + 10 log(Q / 4πr²)
Questions and answers
90 dB at 1 m: what at 10 m?
70 dB from a point source; 80 dB from a line source.
What does a 100 dB sound power source give at 10 m on a floor?
72.0 dB.
Why does it fail indoors?
Reflections keep the level up far from the source.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.