Worked example
Example: Taps 2 m apart, oil 850 / water 1 000, 181 mbar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Distance between the taps | 2.0000 m |
| Density of the lighter liquid (top) | 850.00 kg/m³ |
| Density of the heavier liquid (bottom) | 1,000.0 kg/m³ |
| Measured DP (with the taps fully covered) | 181.00 mbar |
Applying the formula below gives:
| Result | Value |
|---|---|
| DP with interface at the lower tap (all light) | 166.71 mbar |
| DP with interface at the upper tap (all heavy) | 196.13 mbar |
| Interface height above the lower tap | 0.97124 m |
| Interface level as a share of the range | 48.562 % |
Open this example in the calculator and change any input.
Formula
\(\Delta p = g\,[\rho_H h_i + \rho_L (H - h_i)], \quad h_i = \frac{\Delta p - \rho_L g H}{(\rho_H - \rho_L) g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Distance between the taps | m |
| \(\rho_L\) | Density of the lighter liquid (top) | kg/m³ |
| \(\rho_H\) | Density of the heavier liquid (bottom) | kg/m³ |
| \(\Delta p\) | Measured DP (with the taps fully covered) | Pa |
| \(\Delta p_0\) | DP with interface at the lower tap (all light) | Pa |
| \(\Delta p_1\) | DP with interface at the upper tap (all heavy) | Pa |
| \(h_i\) | Interface height above the lower tap | m |
| \(h_i/H\) | Interface level as a share of the range | - |
Method and standards
Hydrostatics of two layers.
Where it is used
- Separators, settlers and desalters.
- Transmitter ranging.
Common mistakes
- Ignoring impulse-line fill.
- Density changes with temperature.
Assumptions and limits
- Both taps covered; clear interface.
References
- Hydrostatics
- Δp = g (ρ_H h + ρ_L (H − h))
Questions and answers
What range for taps 2 m apart, oil 850 and water 1000 kg/m³?
166.7 to 196.1 mbar: a narrow span of 29.4 mbar.
Why is interface DP hard?
The span depends on the density difference, which is small and varies.
What if the top liquid drops below the upper tap?
The reading is wrong; total level must stay above the upper tap.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.