Worked example
Example: 39 m/s at 10 m, 20 m height, open country. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reference wind speed | 39.000 m/s |
| Reference height | 10.000 m |
| Height of interest | 20.000 m |
| Power-law exponent (terrain) | 0.14000 - |
| Air density | 1.2250 kg/m³ |
| Force (shape) coefficient | 1.3000 - |
| Projected area | 20.000 m² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wind speed at z | 42.974 m/s |
| Velocity pressure | 1.1312 kPa |
| Wind force | 29.410 kN |
Open this example in the calculator and change any input.
Formula
\(V_z = V_r\left(\frac{z}{z_r}\right)^\alpha, \quad q_z = \frac12\rho V_z^2, \quad F = C_fq_zA\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_r\) | Reference wind speed | m/s |
| \(z_r\) | Reference height | m |
| \(z\) | Height of interest | m |
| \(\alpha\) | Power-law exponent (terrain) | - |
| \(\rho\) | Air density | kg/m³ |
| \(C_f\) | Force (shape) coefficient | - |
| \(A\) | Projected area | m² |
| \(V_z\) | Wind speed at z | m/s |
| \(q_z\) | Velocity pressure | Pa |
| \(F\) | Wind force | N |
Method and standards
Velocity pressure.
Where it is used
- Wind on stacks, signboards and equipment.
- Checking temporary structures.
Common mistakes
- Using gust and mean speeds interchangeably.
- Omitting code factors in design.
Assumptions and limits
The averaging time of V_r (hourly mean, 10-minute mean or 3-second gust) must match the profile exponent and the code's coefficients; the page does not know which one was entered.
Steady wind; neutral atmosphere.
References
- Velocity pressure q = ½ρV² with the power-law wind profile (Simiu and Scanlan, Wind Effects on Structures)
Questions and answers
Why does wind speed grow with height?
Ground friction slows the wind near the surface; the boundary layer is hundreds of metres deep.
What is a force coefficient?
The ratio of wind force to velocity pressure times area: about 1.2–2 for flat plates and lattice members, 0.5–1.2 for cylinders.
What do the defaults represent?
A 39 m/s reference wind at 10 m, a surface at 20 m in open country, 20 m² with C_f = 1.3.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.