FireCADCalc

Transition (Spiral) Curve Length and Shift

Length of a transition (clothoid) curve from the design speed, circular radius and allowed rate of change of radial acceleration, with the shift and spiral angle.

Inputs

Examples: Illustrative: 80 km/h, R 300 m, C 0.45, e 6 %, 7 m at 1 in 150Expressway 120 km/h, R 1000 m, C 0.3, e 5 %, 11 m at 1 in 200Hill road 40 km/h, R 60 m, C 0.6, e 7 %, 6 m at 1 in 60

Accepted: 3.6 to 360 km/h
Accepted: 10 to 100,000 m
Accepted: 0.1 to 1.5
Accepted: 0 to 15 %
Accepted: 1 to 30 m
Accepted: 50 to 400

Results

Shortt's comfort criterion L = V³/(CR) (V in m/s, C in m/s³) and the length needed to run off the superelevation at 1 in N about the centre line. Design codes add their own minimum lengths.

Transition length by comfort V³/(CR)38.104m
Transition length by superelevation run-off eNW25.200m
Transition length adopted (larger)38.104m
Shift L²/(24R)1.0083m
Spiral angle L/(2R)18.193°
Radial acceleration on the circular curve2.0576m/s²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 80 km/h, R 300 m, C 0.45, e 6 %, 7 m at 1 in 150. The inputs, in the units selected above:

InputValue
Design speed80.000 km/h
Radius of the circular curve300.00 m
Rate of change of radial acceleration (0.3–0.6)0.45000 -
Superelevation6.0000 %
Width rotated (carriageway)7.0000 m
Rate of superelevation change 1 in N150.00 -

Applying the formula below gives:

ResultValue
Transition length by comfort V³/(CR)81.288 m
Transition length by superelevation run-off eNW63.000 m
Transition length adopted (larger)81.288 m
Shift L²/(24R)0.91775 m
Spiral angle L/(2R)7.7625 °
Radial acceleration on the circular curve1.6461 m/s²

Open this example in the calculator and change any input.

Formula

\(L_s = \frac{V^3}{CR}, \quad L_e = eNW, \quad S = \frac{L^2}{24R}, \quad \theta_s = \frac{L}{2R}\)

Variables

Symbol Meaning SI unit
\(V\) Design speed m/s
\(R\) Radius of the circular curve m
\(C\) Rate of change of radial acceleration (0.3–0.6) -
\(e\) Superelevation -
\(W\) Width rotated (carriageway) m
\(N\) Rate of superelevation change 1 in N -
\(L_s\) Transition length by comfort V³/(CR) m
\(L_e\) Transition length by superelevation run-off eNW m
\(L\) Transition length adopted (larger) m
\(S\) Shift L²/(24R) m
\(\theta_s\) Spiral angle L/(2R) rad
\(V^2/R\) Radial acceleration on the circular curve m/s²

Method and standards

Transition curve design.

Where it is used

  • Highway and railway alignment design.
  • Setting out spirals on site.

Common mistakes

  • Mixing km/h and m/s in V³.
  • Forgetting the superelevation run-off criterion.

Assumptions and limits

  • Clothoid spiral, small deflection approximations for the shift.

References

  • Shortt's transition length; superelevation run-off; clothoid shift

Questions and answers

Why are transition curves used?

They let the curvature, and so the sideways acceleration, build up gradually from the straight to the circular curve, and give room to raise the superelevation.

What value of C should I use?

About 0.3 m/s³ for high-speed comfort, up to 0.6 for lower speeds and difficult sites; railways use similar jerk limits.

What do the defaults represent?

An illustrative 80 km/h road curve of 300 m radius with 6 % superelevation on a 7 m carriageway rotated at 1 in 150.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Garber and Hoel, Traffic and Highway Engineering, 5th ed. (Cengage, 2015), ch. 16

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.