Worked example
Example: Illustrative dense mix, 5 % binder. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Bulk specific gravity of compacted mix | 2.3500 - |
| Maximum specific gravity of mix | 2.4500 - |
| Bulk specific gravity of aggregate | 2.6500 - |
| Binder specific gravity | 1.0200 - |
| Binder content (by total mix) | 5.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Air voids | 4.0816 % |
| Voids in mineral aggregate | 15.755 % |
| Voids filled with binder | 74.093 % |
| Effective specific gravity of aggregate | 2.6452 |
| Absorbed binder (by aggregate) | -0.070121 % |
| Effective binder (by mix) | 5.0666 % |
Open this example in the calculator and change any input.
Formula
\(V_a = \frac{G_{mm} - G_{mb}}{G_{mm}}, \quad VMA = 1 - \frac{G_{mb}P_s}{G_{sb}}, \quad VFB = \frac{VMA - V_a}{VMA}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(G_{mb}\) | Bulk specific gravity of compacted mix | - |
| \(G_{mm}\) | Maximum specific gravity of mix | - |
| \(G_{sb}\) | Bulk specific gravity of aggregate | - |
| \(G_b\) | Binder specific gravity | - |
| \(P_b\) | Binder content (by total mix) | - |
| \(V_a\) | Air voids | - |
| \(VMA\) | Voids in mineral aggregate | - |
| \(VFB\) | Voids filled with binder | - |
| \(G_{se}\) | Effective specific gravity of aggregate | - |
| \(P_{ba}\) | Absorbed binder (by aggregate) | - |
| \(P_{be}\) | Effective binder (by mix) | - |
Method and standards
Mix volumetrics.
Where it is used
- Bituminous mix design and plant control.
- Checking cores from laid pavement.
Common mistakes
- Using apparent instead of bulk aggregate gravity for VMA.
- Mixing binder by mix and by aggregate.
Assumptions and limits
- Consistent specific gravities from standard tests.
References
- Asphalt mix volumetric relations
Questions and answers
Why does absorbed binder matter?
Binder soaked into aggregate pores does nothing for coating or durability; only effective binder does.
What do low air voids mean?
Below about 3 % the mix risks bleeding and rutting; above about 6 % it ages and lets water in.
What do the defaults represent?
An illustrative dense mix: G_mb 2.35, G_mm 2.45, G_sb 2.65, G_b 1.02 and 5 % binder.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Asphalt Institute, MS-2 Asphalt Mix Design Methods, 7th ed. (2014)