FireCADCalc

Railway Curve Cant, Cant Deficiency and Equilibrium Speed

Equilibrium cant for a design speed on a railway curve, the cant deficiency at the maximum speed and excess at low speed, and the unbalanced lateral acceleration.

Inputs

Examples: Illustrative broad-gauge 1000 m curveStandard gauge with 100 mm cantTight curve, slow line

Accepted: 500 to 2,000 mm
Accepted: 50 to 20,000 m
Accepted: 3.6 to 360 km/h
Accepted: 3.6 to 360 km/h
Accepted: 3.6 to 360 km/h
Accepted: 0 to 300 mm

Results

Raising the outer rail by C tilts the track so that gravity balances the centripetal acceleration at one speed: C = G v²/(gR), where G is the distance between rail centres. Faster trains run with a cant deficiency (an unbalanced outward acceleration g C_d/G felt by passengers and carried by the rails); slower trains with a cant excess that wears the inner rail. Railways set maximum values for cant, deficiency and excess (for example about 165 mm, 75–100 mm and 75 mm on Indian broad gauge): use your administration's limits.

Equilibrium cant for the equilibrium speed113.30mm
Cant used100.00mm
Cant deficiency at the maximum speed101.43mm
Cant excess at the lowest speed49.644mm
Unbalanced lateral acceleration at the maximum speed0.66310m/s²
Speed for which the cant used is balanced112.74km/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative broad-gauge 1000 m curve. The inputs, in the units selected above:

InputValue
Distance between rail centres (1750 mm broad gauge, 1500 mm standard gauge)1,750.0 mm
Curve radius1,000.0 m
Equilibrium (average) speed80.000 km/h
Maximum speed110.00 km/h
Lowest regular speed (freight)60.000 km/h
Cant actually provided (0 = use the equilibrium cant)0 mm

Applying the formula below gives:

ResultValue
Equilibrium cant for the equilibrium speed88.124 mm
Cant used88.124 mm
Cant deficiency at the maximum speed78.485 mm
Cant excess at the lowest speed38.554 mm
Unbalanced lateral acceleration at the maximum speed0.43981 m/s²
Speed for which the cant used is balanced80.000 km/h

Open this example in the calculator and change any input.

Formula

\(C = \frac{G v^2}{g R}, \quad C_d = \frac{G v_{max}^2}{gR} - C, \quad a_u = \frac{g C_d}{G}\)

Variables

Symbol Meaning SI unit
\(G\) Distance between rail centres (1750 mm broad gauge, 1500 mm standard gauge) m
\(R\) Curve radius m
\(V_e\) Equilibrium (average) speed m/s
\(V_{max}\) Maximum speed m/s
\(V_{min}\) Lowest regular speed (freight) m/s
\(C_a\) Cant actually provided (0 = use the equilibrium cant) m
\(C_e\) Equilibrium cant for the equilibrium speed m
\(C\) Cant used m
\(C_d\) Cant deficiency at the maximum speed m
\(C_x\) Cant excess at the lowest speed m
\(a_u\) Unbalanced lateral acceleration at the maximum speed m/s²
\(V_b\) Speed for which the cant used is balanced m/s

Method and standards

Railway cant.

Where it is used

  • Railway curve design and speed restrictions.
  • Checking existing curves for higher speeds.

Common mistakes

  • Using the track gauge instead of the distance between rail centres.
  • Ignoring the cant excess for slow freight.

Assumptions and limits

  • Steady curving; cant limits from your railway.

References

  • Track geometry: equilibrium cant e = G v²/(gR)

Questions and answers

What cant does a 1,000 m curve need at 80 km/h on broad gauge?

C = 1750 × 22.2²/(9.81 × 1000) = 88 mm.

What is cant deficiency?

The extra cant that would be needed to balance the maximum speed; it is felt as unbalanced lateral acceleration.

What do the defaults represent?

An illustrative broad-gauge curve of 1,000 m radius with 80 km/h equilibrium, 110 km/h maximum and 60 km/h freight speeds.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.