Exit Gradient by Khosla's Theory

Exit gradient at the downstream end of a weir floor with an end cut-off, by Khosla's formula, compared with the safe exit gradient of the soil.

Inputs

Examples: Illustrative 4 m head, 3 m cut-offSilt, 1/7 safeCoarse sand, 1/4

Accepted: 0.1 to 50 m
Accepted: 0.1 to 50 m
Accepted: 0.1 to 1,000 m
Accepted: 0.05 to 0.5

Results

Khosla's analysis of seepage under a floor with a downstream cut-off of depth d gives the exit gradient G_E = H/(dπ√λ), with λ = [1 + √(1 + α²)]/2 and α = b/d. If the gradient at exit exceeds the soil's safe value (about 1/4–1/5 for coarse sand, 1/5–1/6 for fine sand, 1/6–1/7 for silt), the soil can be lifted (piping). Deeper cut-offs or longer floors reduce it; the cut-off depth for the safe gradient is found by iteration.

b/d16.667
λ8.8483
Exit gradient0.21402
Safety ratio (≥ 1 safe)1.1681
Cut-off depth for the safe gradient1.1163m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 4 m head, 3 m cut-off. The inputs, in the units selected above:

InputValue
Seepage head4.0000 m
Depth of the downstream cut-off3.0000 m
Total floor length40.000 m
Safe exit gradient for the soil0.16667 -

Applying the formula below gives:

ResultValue
b/d13.333
λ7.1854
Exit gradient0.15833
Safety ratio (≥ 1 safe)1.0527
Cut-off depth for the safe gradient2.7260 m

Open this example in the calculator and change any input.

Formula

\(G_E = \frac{H}{d\pi\sqrt\lambda}, \quad \lambda = \frac{1 + \sqrt{1 + \alpha^2}}{2}, \quad \alpha = \frac bd\)

Variables

Symbol Meaning SI unit
\(H\) Seepage head m
\(d\) Depth of the downstream cut-off m
\(b\) Total floor length m
\(G_s\) Safe exit gradient for the soil -
\(\alpha\) b/d -
\(\lambda\) λ -
\(G_E\) Exit gradient -
\(G_s/G_E\) Safety ratio (≥ 1 safe) -
\(d_{req}\) Cut-off depth for the safe gradient m

Method and standards

Exit gradient.

Where it is used

  • Weir, barrage and regulator design.
  • Civil engineering examinations.

Common mistakes

  • Using the upstream cut-off depth.
  • Using a safe gradient for the wrong soil.

Assumptions and limits

  • Floor of negligible thickness; homogeneous soil.

References

  • Classical irrigation engineering relations (duty and delta, Bligh and Lane creep, Khosla exit gradient)

Questions and answers

What is the exit gradient for 4 m head, 3 m cut-off and 40 m floor?

About 0.158 (1 in 6.3), just within 1/6 for fine sand.

How can the exit gradient be reduced?

Deepen the downstream cut-off or lengthen the floor.

What do the defaults represent?

An illustrative weir with 4 m seepage head, a 3 m downstream cut-off and a 40 m floor, safe gradient 1/6.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.