FireCADCalc

Immediate (Elastic) Settlement of a Footing

Immediate settlement of a footing on an elastic soil layer from net pressure, width, Poisson's ratio, soil modulus and an influence factor for shape and rigidity.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 2 m rigid square at 150 kPa, E 20 MPa3 m flexible centre on clay, undrained

Results

Influence factors for a semi-infinite layer: square flexible centre 1.12, corner 0.56, average 0.95; square rigid 0.88; circle flexible centre 1.0, rigid 0.79. Saturated clay under undrained loading: ν = 0.5. Consolidation settlement of clay is extra.

Immediate settlement20.160mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 m rigid square at 150 kPa, E 20 MPa. The inputs, in the units selected above:

InputValue
Net foundation pressure150.00 kPa
Footing width2.0000 m
Poisson's ratio of soil0.30000 -
Soil modulus20.000 MPa
Influence factor (shape, rigidity, location)0.88000 -

Applying the formula below gives:

ResultValue
Immediate settlement12.012 mm

Open this example in the calculator and change any input.

Formula

\(S_e = \frac{q_nB(1 - \nu^2)I_f}{E_s}\)

Variables

Symbol Meaning SI unit
\(q_n\) Net foundation pressure Pa
\(B\) Footing width m
\(\nu\) Poisson's ratio of soil -
\(E_s\) Soil modulus Pa
\(I_f\) Influence factor (shape, rigidity, location) -
\(S_e\) Immediate settlement m

Method and standards

Elastic half-space.

Where it is used

  • Equipment and building foundations.
  • Checking differential settlement.

Common mistakes

  • Using a clay modulus for drained loading.
  • Ignoring a stiff layer at shallow depth.

Assumptions and limits

  • Homogeneous elastic soil of semi-infinite depth. No correction for a stiff layer at shallow depth or for embedment; both can reduce the settlement substantially (use depth and thickness correction factors from your text).

References

  • Elastic settlement S_e = qB(1 − ν²)I_f/E_s (Schleicher; Das, Principles of Foundation Engineering, 7th ed. (Cengage, 2011), ch. 5)

Questions and answers

Is this the total settlement?

No: in clays consolidation settlement follows over months or years; in sands immediate settlement is most of it.

Where does E_s come from?

Plate load tests, pressuremeter tests or correlations with SPT or CPT.

What do the defaults represent?

A 2 m rigid square footing at 150 kPa on medium-dense sand (E_s = 20 MPa).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.