Base Pressure under an Eccentrically Loaded Footing

Maximum and minimum soil pressure under a rectangular footing with a vertical load and moments about one or both axes, with the no-tension check and the peak pressure when part of the base lifts.

Inputs

Examples: Biaxial momentsConcentricCorner lifts

Results

Eccentricity along L0m
Eccentricity along B0m
Maximum pressure150.00kPa
Minimum pressure150.00kPa
Average pressure P/(BL)150.00kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Biaxial moments. The inputs, in the units selected above:

InputValue
Vertical load (including footing and soil)900.00 kN
Moment about the axis parallel to B (acts along L)90.000 kN·m
Moment about the axis parallel to L (acts along B)45.000 kN·m
Footing length2.5000 m
Footing width2.0000 m

Applying the formula below gives:

ResultValue
Eccentricity along L0.10000 m
Eccentricity along B0.050000 m
Maximum pressure250.20 kPa
Minimum pressure109.80 kPa
Average pressure P/(BL)180.00 kPa

Open this example in the calculator and change any input.

Formula

\(q = \frac{P}{BL}\left(1 \pm \frac{6e_L}{L} \pm \frac{6e_B}{B}\right), \quad e = \frac{M}{P}\)

When one-way eccentricity exceeds L/6 the base lifts over part of its length; the soil pressure is then triangular over a contact length 3(L/2 − e):

\(q_{max} = \frac{4P}{3B(L - 2e)}, \quad q_{min} = 0\)

Variables

Symbol Meaning SI unit
\(P\) Vertical load (including footing and soil) N
\(M_x\) Moment about the axis parallel to B (acts along L) N·m
\(M_y\) Moment about the axis parallel to L (acts along B) N·m
\(L\) Footing length m
\(B\) Footing width m
\(e_L\) Eccentricity along L m
\(e_B\) Eccentricity along B m
\(q_{max}\) Maximum pressure Pa
\(q_{min}\) Minimum pressure Pa
\(q_{avg}\) Average pressure P/(BL) Pa

Method and standards

Linear pressure distribution.

Where it is used

  • Column and equipment footings.
  • Fan and pump foundations.

Common mistakes

  • Ignoring footing self-weight.
  • Using it when qmin is negative.

Assumptions and limits

  • Rigid footing, linear pressure.

References

  • Linear soil pressure q = P/A (1 ± 6e_L/L ± 6e_B/B)

Questions and answers

900 kN with 90 and 45 kN·m on 2.5 × 2.0 m?

About 250.2 kPa maximum and 109.8 kPa minimum.

What if the minimum is negative?

Part of the base lifts. For a moment about one axis the page then shows the peak 4P/(3B(L − 2e)) over the contact length 3(L/2 − e); for moments about both axes it asks you to enlarge the footing.

Compare with?

The allowable bearing pressure of the soil.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.