Worked example
Example: Biaxial moments. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vertical load (including footing and soil) | 900.00 kN |
| Moment about the axis parallel to B (acts along L) | 90.000 kN·m |
| Moment about the axis parallel to L (acts along B) | 45.000 kN·m |
| Footing length | 2.5000 m |
| Footing width | 2.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Eccentricity along L | 0.10000 m |
| Eccentricity along B | 0.050000 m |
| Maximum pressure | 250.20 kPa |
| Minimum pressure | 109.80 kPa |
| Average pressure P/(BL) | 180.00 kPa |
Open this example in the calculator and change any input.
Formula
\(q = \frac{P}{BL}\left(1 \pm \frac{6e_L}{L} \pm \frac{6e_B}{B}\right), \quad e = \frac{M}{P}\)
When one-way eccentricity exceeds L/6 the base lifts over part of its length; the soil pressure is then triangular over a contact length 3(L/2 − e):
\(q_{max} = \frac{4P}{3B(L - 2e)}, \quad q_{min} = 0\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Vertical load (including footing and soil) | N |
| \(M_x\) | Moment about the axis parallel to B (acts along L) | N·m |
| \(M_y\) | Moment about the axis parallel to L (acts along B) | N·m |
| \(L\) | Footing length | m |
| \(B\) | Footing width | m |
| \(e_L\) | Eccentricity along L | m |
| \(e_B\) | Eccentricity along B | m |
| \(q_{max}\) | Maximum pressure | Pa |
| \(q_{min}\) | Minimum pressure | Pa |
| \(q_{avg}\) | Average pressure P/(BL) | Pa |
Method and standards
Linear pressure distribution.
Where it is used
- Column and equipment footings.
- Fan and pump foundations.
Common mistakes
- Ignoring footing self-weight.
- Using it when qmin is negative.
Assumptions and limits
- Rigid footing, linear pressure.
References
- Linear soil pressure q = P/A (1 ± 6e_L/L ± 6e_B/B)
Questions and answers
900 kN with 90 and 45 kN·m on 2.5 × 2.0 m?
About 250.2 kPa maximum and 109.8 kPa minimum.
What if the minimum is negative?
Part of the base lifts. For a moment about one axis the page then shows the peak 4P/(3B(L − 2e)) over the contact length 3(L/2 − e); for moments about both axes it asks you to enlarge the footing.
Compare with?
The allowable bearing pressure of the soil.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.