Ideal dilute solution; real brines deviate (use an osmotic coefficient), and complete dissociation is assumed by i.

Osmotic pressure2.5205bar
Equivalent water head25.702m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Seawater-like NaCl. The inputs, in the units selected above:

InputValue
Molar concentration of solute0.60000 mol/L
van 't Hoff factor (ions per formula unit)2.0000 -
Temperature25.000 °C

Applying the formula below gives:

ResultValue
Osmotic pressure29.747 bar
Equivalent water head303.34 m

Open this example in the calculator and change any input.

Formula

\(\pi = i\, c\, R\, T\)

Variables

Symbol Meaning SI unit
\(c\) Molar concentration of solute mol/m³
\(i\) van 't Hoff factor (ions per formula unit) -
\(T\) Temperature K
\(\pi\) Osmotic pressure Pa
\(h\) Equivalent water head m

Method and standards

van 't Hoff.

Where it is used

  • RO plant feed pressure estimates.
  • Examinations.

Common mistakes

  • mol/L used as mol/m³.
  • Ideal value for strong brines.

Assumptions and limits

  • Dilute ideal solution with complete dissociation. Concentrated brines have an osmotic coefficient below 1 (about 0.9 for seawater), so the ideal result is high: 0.6 mol/L NaCl gives 29.7 bar ideal against about 27 bar measured. Multiply by the osmotic coefficient when it is known.

References

  • van 't Hoff π = i c R T

Questions and answers

0.6 mol/L NaCl (near seawater) at 25 °C?

About 29.7 bar ideal (measured seawater is about 27 bar).

Why does RO need more?

The applied pressure must exceed the osmotic pressure plus losses to push water through.

Brackish water?

Lower concentration, far lower pressure.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.