FireCADCalc

Shell-and-Tube Exchanger: Tube-Side Velocity and Reynolds Number

Tube-side velocity and Reynolds number of a shell-and-tube exchanger from flow, fluid properties, tube bore, tube count and passes.

Refinery and petrochemicalChemical and fertiliser

Inputs

Examples: Water, 292 tubes, 2 passesOil, 100 tubes, 4 passes

Results

Typical liquid velocities are 1–2.5 m/s to limit fouling without erosion; your design guide decides.

Tube-side velocity1.4979m/s
Reynolds number5,093.0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water, 292 tubes, 2 passes. The inputs, in the units selected above:

InputValue
Tube-side mass flow108,000 kg/h
Fluid density995.00 kg/m³
Fluid viscosity8.0000e-04 Pa·s
Tube inside diameter15.750 mm
Number of tubes292.00 -
Tube passes2.0000 -

Applying the formula below gives:

ResultValue
Tube-side velocity1.0600 m/s
Reynolds number20,764

Open this example in the calculator and change any input.

Formula

\(v = \frac{\dot m}{\rho\frac{N}{n_p}\frac{\pi d_i^2}{4}}, \quad Re = \frac{\rho v d_i}{\mu}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Tube-side mass flow kg/s
\(\rho\) Fluid density kg/m³
\(\mu\) Fluid viscosity Pa·s
\(d_i\) Tube inside diameter m
\(N\) Number of tubes -
\(n_p\) Tube passes -
\(v\) Tube-side velocity m/s
\(Re\) Reynolds number -

Method and standards

Continuity.

Where it is used

  • Exchanger rating.
  • Cooling water exchangers.

Common mistakes

  • All tubes instead of tubes per pass.
  • Outside diameter.

Assumptions and limits

  • Equal flow in every tube.

References

  • Continuity per pass v = ṁ/(ρ (N/n_p) π d_i²/4)

Questions and answers

30 kg/s of water in 292 tubes, two passes, 15.75 mm bore?

About 1.06 m/s, Re about 20,764.

Too low?

Add passes to raise velocity and heat transfer, at more pressure drop.

Too high?

Erosion and vibration; reduce passes.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.