Worked example
Example: Solvent overhead. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour flow | 3,000.0 kg/h |
| Vapour specific heat at constant pressure | 1.7000 kJ/(kg·K) |
| Superheat to remove | 30.000 K |
| Latent heat at the condensing temperature | 400.00 kJ/kg |
| Liquid specific heat | 2.1000 kJ/(kg·K) |
| Sub-cooling | 10.000 K |
| Cooling water specific heat | 4.1800 kJ/(kg·K) |
| Cooling water temperature rise | 8.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Desuperheating | 42.500 kW |
| Condensing | 333.33 kW |
| Sub-cooling | 17.500 kW |
| Total duty | 393.33 kW |
| Cooling water | 42.344 t/h |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m\left[c_v \Delta T_{sh} + \lambda + c_l \Delta T_{sc}\right], \quad \dot m_w = \frac{\dot Q}{c_w \Delta T_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Vapour flow | kg/s |
| \(c_v\) | Vapour specific heat at constant pressure | J/(kg·K) |
| \(\Delta T_{sh}\) | Superheat to remove | K |
| \(\lambda\) | Latent heat at the condensing temperature | J/kg |
| \(c_l\) | Liquid specific heat | J/(kg·K) |
| \(\Delta T_{sc}\) | Sub-cooling | K |
| \(c_w\) | Cooling water specific heat | J/(kg·K) |
| \(\Delta T_w\) | Cooling water temperature rise | K |
| \(\dot Q_{sh}\) | Desuperheating | W |
| \(\dot Q_{c}\) | Condensing | W |
| \(\dot Q_{sc}\) | Sub-cooling | W |
| \(\dot Q\) | Total duty | W |
| \(\dot m_w\) | Cooling water | kg/s |
Method and standards
Energy balance.
Where it is used
- Column overhead and solvent condensers.
- Cooling water planning.
Common mistakes
- Latent heat at the wrong pressure.
- One overall LMTD for all zones.
Assumptions and limits
- Pure vapour.
- c_v is the vapour's constant-pressure specific heat (v for vapour).
References
- Energy balance by zones: sensible
- latent
- sensible
Questions and answers
3000 kg/h with 30 K superheat, 400 kJ/kg latent, 10 K sub-cool?
About 393 kW, mostly latent; 42.3 t/h of water at 8 K rise.
Why split into zones?
Each zone's LMTD and coefficient differ; one average misleads.
Non-condensables?
They lower the coefficient sharply; vent them.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.