Pinch Analysis: Minimum Hot and Cold Utilities (Problem Table)

Minimum hot and cold utility, heat recovery and pinch temperatures for up to two hot and two cold streams by the problem table algorithm at a chosen ΔT_min.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Kemp's four-stream example, ΔTmin 10 K (QH 20, QC 60 kW)Same, ΔTmin 20 KOne hot, one cold, threshold

Results

Do not transfer heat across the pinch, use no hot utility below it and no cold utility above it.

Minimum hot utility65.000kW
Minimum cold utility105.00kW
Heat recovered405.00kW
Pinch temperature, hot side100.00°C
Pinch temperature, cold side80.000°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Kemp's four-stream example, ΔTmin 10 K (QH 20, QC 60 kW). The inputs, in the units selected above:

InputValue
Hot stream 1 supply170.00 °C
Hot stream 1 target60.000 °C
Hot stream 1 heat capacity flow3.0000 kW/K
Hot stream 2 supply150.00 °C
Hot stream 2 target30.000 °C
Hot stream 2 CP (0 = none)1.5000 kW/K
Cold stream 1 supply20.000 °C
Cold stream 1 target135.00 °C
Cold stream 1 CP2.0000 kW/K
Cold stream 2 supply80.000 °C
Cold stream 2 target140.00 °C
Cold stream 2 CP (0 = none)4.0000 kW/K
Minimum approach10.000 K

Applying the formula below gives:

ResultValue
Minimum hot utility20.000 kW
Minimum cold utility60.000 kW
Heat recovered450.00 kW
Pinch temperature, hot side90.000 °C
Pinch temperature, cold side80.000 °C

Open this example in the calculator and change any input.

Formula

\(T^* = T - \frac{\Delta T_{min}}{2}\ \text{(hot)}, \ T^* = T + \frac{\Delta T_{min}}{2}\ \text{(cold)}, \quad \Delta H_i = \left(\sum CP_H - \sum CP_C\right)_i\Delta T^*_i\)

\(Q_{H,min} = -\min_k\sum_{i\le k}\Delta H_i, \quad Q_{C,min} = Q_{H,min} + \sum_i\Delta H_i\)

Variables

Symbol Meaning SI unit
\(T_{s,H1}\) Hot stream 1 supply K
\(T_{t,H1}\) Hot stream 1 target K
\(CP_{H1}\) Hot stream 1 heat capacity flow W/K
\(T_{s,H2}\) Hot stream 2 supply K
\(T_{t,H2}\) Hot stream 2 target K
\(CP_{H2}\) Hot stream 2 CP (0 = none) W/K
\(T_{s,C1}\) Cold stream 1 supply K
\(T_{t,C1}\) Cold stream 1 target K
\(CP_{C1}\) Cold stream 1 CP W/K
\(T_{s,C2}\) Cold stream 2 supply K
\(T_{t,C2}\) Cold stream 2 target K
\(CP_{C2}\) Cold stream 2 CP (0 = none) W/K
\(\Delta T_{min}\) Minimum approach K
\(Q_{H,min}\) Minimum hot utility W
\(Q_{C,min}\) Minimum cold utility W
\(Q_{rec}\) Heat recovered W
\(T_{pinch,hot}\) Pinch temperature, hot side K
\(T_{pinch,cold}\) Pinch temperature, cold side K

Method and standards

Problem table algorithm.

Where it is used

  • Energy targets for process plants, distilleries and sugar factories.
  • Checking an existing exchanger network.

Common mistakes

  • Entering streams with phase change as a single CP.
  • Using actual instead of shifted temperatures.

Assumptions and limits

  • Constant CP per stream; up to 2 hot and 2 cold streams.
  • Threshold problems (no hot utility, or no cold utility) are named in the note.

References

  • Linnhoff and Flower (1978)
  • AIChE J. 24: 633 (problem table algorithm); Kemp
  • Pinch Analysis and Process Integration
  • 2nd ed. (Butterworth-Heinemann, 2007)

Questions and answers

What is the pinch?

The point where hot and cold composite curves come closest (ΔT_min); it splits the process into a heat sink above and a heat source below.

What do the defaults give?

Kemp's four-stream example at ΔT_min 10 K: 20 kW hot and 60 kW cold utility (in kW/K units), pinch at 90 °C hot / 80 °C cold.

How do I choose ΔT_min?

Trade energy against exchanger area: 10–20 K for liquids, 20–40 K for gases.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.