Worked example
Example: Kemp's four-stream example, ΔTmin 10 K (QH 20, QC 60 kW). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hot stream 1 supply | 170.00 °C |
| Hot stream 1 target | 60.000 °C |
| Hot stream 1 heat capacity flow | 3.0000 kW/K |
| Hot stream 2 supply | 150.00 °C |
| Hot stream 2 target | 30.000 °C |
| Hot stream 2 CP (0 = none) | 1.5000 kW/K |
| Cold stream 1 supply | 20.000 °C |
| Cold stream 1 target | 135.00 °C |
| Cold stream 1 CP | 2.0000 kW/K |
| Cold stream 2 supply | 80.000 °C |
| Cold stream 2 target | 140.00 °C |
| Cold stream 2 CP (0 = none) | 4.0000 kW/K |
| Minimum approach | 10.000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Minimum hot utility | 20.000 kW |
| Minimum cold utility | 60.000 kW |
| Heat recovered | 450.00 kW |
| Pinch temperature, hot side | 90.000 °C |
| Pinch temperature, cold side | 80.000 °C |
Open this example in the calculator and change any input.
Formula
\(T^* = T - \frac{\Delta T_{min}}{2}\ \text{(hot)}, \ T^* = T + \frac{\Delta T_{min}}{2}\ \text{(cold)}, \quad \Delta H_i = \left(\sum CP_H - \sum CP_C\right)_i\Delta T^*_i\)
\(Q_{H,min} = -\min_k\sum_{i\le k}\Delta H_i, \quad Q_{C,min} = Q_{H,min} + \sum_i\Delta H_i\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{s,H1}\) | Hot stream 1 supply | K |
| \(T_{t,H1}\) | Hot stream 1 target | K |
| \(CP_{H1}\) | Hot stream 1 heat capacity flow | W/K |
| \(T_{s,H2}\) | Hot stream 2 supply | K |
| \(T_{t,H2}\) | Hot stream 2 target | K |
| \(CP_{H2}\) | Hot stream 2 CP (0 = none) | W/K |
| \(T_{s,C1}\) | Cold stream 1 supply | K |
| \(T_{t,C1}\) | Cold stream 1 target | K |
| \(CP_{C1}\) | Cold stream 1 CP | W/K |
| \(T_{s,C2}\) | Cold stream 2 supply | K |
| \(T_{t,C2}\) | Cold stream 2 target | K |
| \(CP_{C2}\) | Cold stream 2 CP (0 = none) | W/K |
| \(\Delta T_{min}\) | Minimum approach | K |
| \(Q_{H,min}\) | Minimum hot utility | W |
| \(Q_{C,min}\) | Minimum cold utility | W |
| \(Q_{rec}\) | Heat recovered | W |
| \(T_{pinch,hot}\) | Pinch temperature, hot side | K |
| \(T_{pinch,cold}\) | Pinch temperature, cold side | K |
Method and standards
Problem table algorithm.
Where it is used
- Energy targets for process plants, distilleries and sugar factories.
- Checking an existing exchanger network.
Common mistakes
- Entering streams with phase change as a single CP.
- Using actual instead of shifted temperatures.
Assumptions and limits
- Constant CP per stream; up to 2 hot and 2 cold streams.
- Threshold problems (no hot utility, or no cold utility) are named in the note.
References
- Linnhoff and Flower (1978)
- AIChE J. 24: 633 (problem table algorithm); Kemp
- Pinch Analysis and Process Integration
- 2nd ed. (Butterworth-Heinemann, 2007)
Questions and answers
What is the pinch?
The point where hot and cold composite curves come closest (ΔT_min); it splits the process into a heat sink above and a heat source below.
What do the defaults give?
Kemp's four-stream example at ΔT_min 10 K: 20 kW hot and 60 kW cold utility (in kW/K units), pinch at 90 °C hot / 80 °C cold.
How do I choose ΔT_min?
Trade energy against exchanger area: 10–20 K for liquids, 20–40 K for gases.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.