Worked example
Example: Steam jacket, 10 t, 20 to 90 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Arrangement | Jacket or coil, isothermal medium (steam) |
| Batch mass | 10,000 kg |
| Batch specific heat | 3.5000 kJ/(kg·K) |
| Overall coefficient | 400.00 W/(m²·K) |
| Heat-transfer area | 15.000 m² |
| Heating medium inlet temperature | 140.00 °C |
| Initial batch temperature | 20.000 °C |
| Final batch temperature | 90.000 °C |
| Heating liquid flow | 10,800 kg/h |
| Heating liquid specific heat | 2.3000 kJ/(kg·K) |
| Batch recirculation through the external exchanger | 14,400 kg/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heating time | 1.4186 h |
| Heat to the batch | 680.56 kWh |
| Average duty | 479.74 kW |
Open this example in the calculator and change any input.
Formula
\(\ln\frac{T_1 - t_1}{T_1 - t_2} = \frac{UA}{Mc}\theta\ \text{(isothermal medium)}, \quad \ln\frac{T_1 - t_1}{T_1 - t_2} = \frac{WC}{Mc}\frac{K_1 - 1}{K_1}\theta, \ K_1 = e^{UA/WC}\)
\(\ln\frac{T_1 - t_1}{T_1 - t_2} = \frac{w}{M}\frac{K_2 - 1}{K_2}\theta, \ K_2 = e^{UA/wc}, \quad \ln\frac{T_1 - t_1}{T_1 - t_2} = \frac{K_3 - 1}{M}\frac{wWC}{K_3wc - WC}\theta, \ K_3 = e^{UA(1/WC - 1/wc)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{config}\) | Arrangement | - |
| \(M\) | Batch mass | kg |
| \(c\) | Batch specific heat | J/(kg·K) |
| \(U\) | Overall coefficient | W/(m²·K) |
| \(A\) | Heat-transfer area | m² |
| \(T_1\) | Heating medium inlet temperature | K |
| \(t_1\) | Initial batch temperature | K |
| \(t_2\) | Final batch temperature | K |
| \(W\) | Heating liquid flow | kg/s |
| \(C\) | Heating liquid specific heat | J/(kg·K) |
| \(w\) | Batch recirculation through the external exchanger | kg/s |
| \(\theta\) | Heating time | s |
| \(Q\) | Heat to the batch | J |
| \(\bar P\) | Average duty | W |
Method and standards
Perry's batch heating equations (counterflow external exchanger).
Where it is used
- Reactor and tank heat-up.
- Molasses, oil and process batch heating.
Common mistakes
- Using an average U from a different batch temperature.
- Ignoring heat loss on long heat-ups.
Assumptions and limits
- Constant U and flows; counterflow external exchanger.
- Only the inputs the chosen arrangement uses are checked. With a hot liquid, its outlet stays above the batch temperature by the form of the equations.
- Very large UA against a small flow is handled by the limit of the exponential terms (no overflow).
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 11
- Eqs. (11-35) to (11-35f) (batch heating of vessels; Bowman, Mueller and Nagle; Kern)
Questions and answers
Why is heating slower with a hot liquid than with steam?
The liquid cools as it passes the surface, so the mean driving force is smaller.
When is an external exchanger better?
When the vessel's own surface is too small, or the batch is viscous and a jacket transfers poorly.
What do the defaults give?
10 t at 3.5 kJ/(kg·K), 20 → 90 °C with 140 °C steam on 15 m² at 400 W/(m²·K): about 1.4 h.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.