FireCADCalc

Raw Mix Proportioning: Three Components to LSF and Silica Ratio

Proportions of three raw materials for a target Kind's lime saturation factor and silica ratio, with the alumina ratio and hydraulic modulus of the mix.

Inputs

Examples: Duda Example 2.4: limestone, clay, pyrite ash (KS 0.92, SR 2.7)Duda Example 2.5 data (corrected arithmetic): limestone, slag, pyrite ashLimestone, shale and sand (KS 0.92, SR 2.6)

Results

Dry-basis proportions. Duda's Example 2.5 prints 69.95 / 27.73 / 2.32 %, but carries an arithmetic slip in a₁ (−31.104 instead of −30.204); the correct solution of his data is 70.57 / 27.15 / 2.28 %.

Material 170.565%
Material 227.153%
Material 32.2821%
Alumina ratio of the mix1.0105
Hydraulic modulus of the mix2.0867

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Duda Example 2.4: limestone, clay, pyrite ash (KS 0.92, SR 2.7). The inputs, in the units selected above:

InputValue
Target Kind's lime saturation factor0.92000 -
Target silica ratio2.7000 -
SiO₂ in material 10.95000 %
Al₂O₃ in material 10.92000 %
Fe₂O₃ in material 10.38000 %
CaO in material 154.600 %
SiO₂ in material 268.000 %
Al₂O₃ in material 212.600 %
Fe₂O₃ in material 22.9500 %
CaO in material 25.7000 %
SiO₂ in material 3 (corrective)11.000 %
Al₂O₃ in material 3 (corrective)1.5000 %
Fe₂O₃ in material 3 (corrective)84.200 %
CaO in material 3 (corrective)0.76000 %

Applying the formula below gives:

ResultValue
Material 178.309 %
Material 220.215 %
Material 31.4765 %
Alumina ratio of the mix1.5393
Hydraulic modulus of the mix2.1874

Open this example in the calculator and change any input.

Formula

\(\sum_j w_j\left[2.8\,KS\,S_j + 1.65A_j + 0.35F_j - C_j\right] = 0, \quad \sum_j w_j\left[SR(A_j + F_j) - S_j\right] = 0, \quad \sum_j w_j = 1\)

Variables

Symbol Meaning SI unit
\(KS\) Target Kind's lime saturation factor -
\(SR\) Target silica ratio -
\(S_{1}\) SiO₂ in material 1 -
\(A_{1}\) Al₂O₃ in material 1 -
\(F_{1}\) Fe₂O₃ in material 1 -
\(C_{1}\) CaO in material 1 -
\(S_{2}\) SiO₂ in material 2 -
\(A_{2}\) Al₂O₃ in material 2 -
\(F_{2}\) Fe₂O₃ in material 2 -
\(C_{2}\) CaO in material 2 -
\(S_{3}\) SiO₂ in material 3 (corrective) -
\(A_{3}\) Al₂O₃ in material 3 (corrective) -
\(F_{3}\) Fe₂O₃ in material 3 (corrective) -
\(C_{3}\) CaO in material 3 (corrective) -
\(w_1\) Material 1 -
\(w_2\) Material 2 -
\(w_3\) Material 3 -
\(AR\) Alumina ratio of the mix -
\(HM\) Hydraulic modulus of the mix -

Method and standards

Two balances and the sum of parts.

Where it is used

  • Raw mix design and quarry planning.
  • Choosing correctives.

Common mistakes

  • Entering analyses with loss on ignition on different bases.
  • Expecting the alumina ratio to be set too (needs four components).

Assumptions and limits

  • Kind's factor as the lime target.

References

  • Duda
  • Cement Data Book
  • Vol. 1
  • 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
  • secs. 2.4-2.5
  • Examples 2.4 and 2.5

Questions and answers

Which three materials are typical?

A lime component (limestone), a clay or shale for silica and alumina, and a corrective such as sand, iron ore or pyrite ash.

Why can the proportions come out negative?

The targets must lie inside what the three materials can make; otherwise a different corrective is needed.

What do the defaults represent?

Duda's Example 2.4: limestone, clay and pyrite ash to Kind's factor 0.92 and silica ratio 2.7 (78.26 / 20.24 / 1.50 %).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.