FireCADCalc

Coal Ash Absorbed by Clinker

Coal ash absorbed by clinker, from the analyses of raw mix, clinker and coal ash (four oxide balances), and the share of the fired ash that ends up in clinker.

Inputs

Examples: Duda Example 2.6Preheater kiln, coal 18 % ashShort kiln, high dust loss

Results

The four balances should agree; a large spread means unrepresentative samples or dust and volatile losses. Long and preheater kilns absorb nearly all ash; short kilns with high dust loss 30–100 % (Duda).

The oxide balances differ by more than 1 % of clinker: check the analyses.

Absorption from the CaO balance0.94488%
Absorption from the SiO₂ balance0.89820%
Absorption from the Al₂O₃ balance1.0101%
Absorption from the Fe₂O₃ balance2.1277%
Coal ash absorbed (mean, % of clinker)1.2452%
Coal ash fired per kg clinker22.154kg/t
Share of the fired ash absorbed56.207%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Duda Example 2.6. The inputs, in the units selected above:

InputValue
SiO₂ in the raw mix (ignited)19.000 %
Al₂O₃ in the raw mix (ignited)8.2500 %
Fe₂O₃ in the raw mix (ignited)2.8000 %
CaO in the raw mix (ignited)66.600 %
SiO₂ in the clinker19.850 %
Al₂O₃ in the clinker8.9200 %
Fe₂O₃ in the clinker3.3100 %
CaO in the clinker64.450 %
SiO₂ in the coal ash42.950 %
Al₂O₃ in the coal ash27.880 %
Fe₂O₃ in the coal ash17.600 %
CaO in the coal ash4.9500 %
Specific heat consumption3,600.0 kJ/kg
Net calorific value of the coal25.000 MJ/kg
Ash in the coal25.000 %

Applying the formula below gives:

ResultValue
Absorption from the CaO balance3.4874 %
Absorption from the SiO₂ balance3.5491 %
Absorption from the Al₂O₃ balance3.4131 %
Absorption from the Fe₂O₃ balance3.4459 %
Coal ash absorbed (mean, % of clinker)3.4739 %
Coal ash fired per kg clinker36.000 kg/t
Share of the fired ash absorbed96.497 %

Open this example in the calculator and change any input.

Formula

\(q_X = \frac{X_k - X_m}{X_a - X_m}, \quad q = \frac{q_C + q_S + q_A + q_F}{4}, \quad a_{in} = \frac{q_{heat}}{NCV}a_c\)

Variables

Symbol Meaning SI unit
\(S_{m}\) SiO₂ in the raw mix (ignited) -
\(A_{m}\) Al₂O₃ in the raw mix (ignited) -
\(F_{m}\) Fe₂O₃ in the raw mix (ignited) -
\(C_{m}\) CaO in the raw mix (ignited) -
\(S_{k}\) SiO₂ in the clinker -
\(A_{k}\) Al₂O₃ in the clinker -
\(F_{k}\) Fe₂O₃ in the clinker -
\(C_{k}\) CaO in the clinker -
\(S_{a}\) SiO₂ in the coal ash -
\(A_{a}\) Al₂O₃ in the coal ash -
\(F_{a}\) Fe₂O₃ in the coal ash -
\(C_{a}\) CaO in the coal ash -
\(q\) Specific heat consumption J/kg
\(NCV\) Net calorific value of the coal J/kg
\(a_c\) Ash in the coal -
\(q_C\) Absorption from the CaO balance -
\(q_S\) Absorption from the SiO₂ balance -
\(q_A\) Absorption from the Al₂O₃ balance -
\(q_F\) Absorption from the Fe₂O₃ balance -
\(a_{in}\) Coal ash fired per kg clinker kg/kg
\(q/a_{in}\) Share of the fired ash absorbed -

Method and standards

Oxide balances of raw mix, ash and clinker.

Where it is used

  • Raw mix correction for coal firing.
  • Comparing kiln systems.

Common mistakes

  • Using raw meal with loss on ignition.
  • Ignoring alkali and sulphur volatility.

Assumptions and limits

  • All four oxides conserved.

References

  • Duda
  • Cement Data Book
  • Vol. 1
  • 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
  • sec. 2.6 and Example 2.6

Questions and answers

Why does ash matter in raw mix design?

Coal ash is rich in silica and alumina; absorbed into clinker it lowers the lime saturation, so the raw mix must be made correspondingly richer in lime.

Why can the share exceed what was fired?

Sampling and analysis errors; the share should be close to 100 % in preheater kilns.

What do the defaults represent?

Duda's Example 2.6 analyses (3.47 % ash absorbed), with 3,600 kJ/kg clinker from coal of 25 MJ/kg and 25 % ash.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.