Worked example
Example: Duda Example 2.6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| SiO₂ in the raw mix (ignited) | 19.000 % |
| Al₂O₃ in the raw mix (ignited) | 8.2500 % |
| Fe₂O₃ in the raw mix (ignited) | 2.8000 % |
| CaO in the raw mix (ignited) | 66.600 % |
| SiO₂ in the clinker | 19.850 % |
| Al₂O₃ in the clinker | 8.9200 % |
| Fe₂O₃ in the clinker | 3.3100 % |
| CaO in the clinker | 64.450 % |
| SiO₂ in the coal ash | 42.950 % |
| Al₂O₃ in the coal ash | 27.880 % |
| Fe₂O₃ in the coal ash | 17.600 % |
| CaO in the coal ash | 4.9500 % |
| Specific heat consumption | 3,600.0 kJ/kg |
| Net calorific value of the coal | 25.000 MJ/kg |
| Ash in the coal | 25.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Absorption from the CaO balance | 3.4874 % |
| Absorption from the SiO₂ balance | 3.5491 % |
| Absorption from the Al₂O₃ balance | 3.4131 % |
| Absorption from the Fe₂O₃ balance | 3.4459 % |
| Coal ash absorbed (mean, % of clinker) | 3.4739 % |
| Coal ash fired per kg clinker | 36.000 kg/t |
| Share of the fired ash absorbed | 96.497 % |
Open this example in the calculator and change any input.
Formula
\(q_X = \frac{X_k - X_m}{X_a - X_m}, \quad q = \frac{q_C + q_S + q_A + q_F}{4}, \quad a_{in} = \frac{q_{heat}}{NCV}a_c\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_{m}\) | SiO₂ in the raw mix (ignited) | - |
| \(A_{m}\) | Al₂O₃ in the raw mix (ignited) | - |
| \(F_{m}\) | Fe₂O₃ in the raw mix (ignited) | - |
| \(C_{m}\) | CaO in the raw mix (ignited) | - |
| \(S_{k}\) | SiO₂ in the clinker | - |
| \(A_{k}\) | Al₂O₃ in the clinker | - |
| \(F_{k}\) | Fe₂O₃ in the clinker | - |
| \(C_{k}\) | CaO in the clinker | - |
| \(S_{a}\) | SiO₂ in the coal ash | - |
| \(A_{a}\) | Al₂O₃ in the coal ash | - |
| \(F_{a}\) | Fe₂O₃ in the coal ash | - |
| \(C_{a}\) | CaO in the coal ash | - |
| \(q\) | Specific heat consumption | J/kg |
| \(NCV\) | Net calorific value of the coal | J/kg |
| \(a_c\) | Ash in the coal | - |
| \(q_C\) | Absorption from the CaO balance | - |
| \(q_S\) | Absorption from the SiO₂ balance | - |
| \(q_A\) | Absorption from the Al₂O₃ balance | - |
| \(q_F\) | Absorption from the Fe₂O₃ balance | - |
| \(a_{in}\) | Coal ash fired per kg clinker | kg/kg |
| \(q/a_{in}\) | Share of the fired ash absorbed | - |
Method and standards
Oxide balances of raw mix, ash and clinker.
Where it is used
- Raw mix correction for coal firing.
- Comparing kiln systems.
Common mistakes
- Using raw meal with loss on ignition.
- Ignoring alkali and sulphur volatility.
Assumptions and limits
- All four oxides conserved.
References
- Duda
- Cement Data Book
- Vol. 1
- 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
- sec. 2.6 and Example 2.6
Questions and answers
Why does ash matter in raw mix design?
Coal ash is rich in silica and alumina; absorbed into clinker it lowers the lime saturation, so the raw mix must be made correspondingly richer in lime.
Why can the share exceed what was fired?
Sampling and analysis errors; the share should be close to 100 % in preheater kilns.
What do the defaults represent?
Duda's Example 2.6 analyses (3.47 % ash absorbed), with 3,600 kJ/kg clinker from coal of 25 MJ/kg and 25 % ash.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.