FireCADCalc

Cement Moduli: LSF, Silica Ratio, Alumina Ratio, Hydraulic Modulus

Lime saturation factor (Kühl I and II, with MgO), Kind's lime factor, hydraulic modulus, silica ratio, alumina ratio and silicic acid ratio of clinker or raw mix.

Inputs

Examples: Duda Table 2.3 clinker (KS 0.92)Duda Table 2.4 clinkerHigh-iron clinker (AR below 0.64)

Results

Duda's ranges: hydraulic modulus 1.7–2.3, silica ratio 1.9–3.2 (preferred 2.2–2.6), alumina ratio 1.5–2.5, lime standard 90–95 % for ordinary and 95–98 % for high early strength cement.

Hydraulic modulus2.1333
Silica ratio2.5294
Alumina ratio0.54545
Silicic acid ratio7.1667
Lime standard I (Kühl)0.95026
Lime saturation factor (Kühl II, British LSF)0.95075
Lime saturation with MgO (up to 2 %)0.96747
Kind's lime saturation factor0.94435

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Duda Table 2.3 clinker (KS 0.92). The inputs, in the units selected above:

InputValue
CaO66.470 %
SiO₂21.270 %
Al₂O₃6.4900 %
Fe₂O₃2.7500 %
MgO1.6900 %

Applying the formula below gives:

ResultValue
Hydraulic modulus2.1786
Silica ratio2.3019
Alumina ratio2.3600
Silicic acid ratio3.2773
Lime standard I (Kühl)0.93321
Lime saturation factor (Kühl II, British LSF)0.96331
Lime saturation with MgO (up to 2 %)0.98168
Kind's lime saturation factor0.92013

Open this example in the calculator and change any input.

Formula

\(LSF = \frac{C}{2.8S + 1.18A + 0.65F}, \quad SR = \frac{S}{A + F}, \quad AR = \frac{A}{F}, \quad HM = \frac{C}{S + A + F}, \quad KS_K = \frac{C - (1.65A + 0.35F)}{2.8S}\)

Variables

Symbol Meaning SI unit
\(C\) CaO -
\(S\) SiO₂ -
\(A\) Al₂O₃ -
\(F\) Fe₂O₃ -
\(M\) MgO -
\(HM\) Hydraulic modulus -
\(SR\) Silica ratio -
\(AR\) Alumina ratio -
\(S/A\) Silicic acid ratio -
\(KSt\,I\) Lime standard I (Kühl) -
\(LSF\) Lime saturation factor (Kühl II, British LSF) -
\(LSF_{MgO}\) Lime saturation with MgO (up to 2 %) -
\(KS_K\) Kind's lime saturation factor -

Method and standards

Cement moduli.

Where it is used

  • Raw mix control and kiln feed targets.
  • Comparing clinker from different plants.

Common mistakes

  • Using a raw meal analysis with loss on ignition for clinker moduli (ratios are unaffected, LSF too).
  • Mixing the formulas from different standards.

Assumptions and limits

  • Oxide analysis on the same basis.

References

  • Duda
  • Cement Data Book
  • Vol. 1
  • 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
  • secs. 1.7-1.8 (Kühl, Kind)

Questions and answers

Which LSF formula should I use?

Kühl's lime standard II (2.8 S + 1.18 A + 0.65 F) is the usual one and equals the British LSF; Kind's factor is used in Eastern Europe.

Why does the formula change below AR 0.64?

With little alumina all of it binds as ferrite, so the lime bound per unit Al₂O₃ and Fe₂O₃ changes.

What do the defaults represent?

The clinker of Duda's Table 2.3 (66.47 % CaO, 21.27 % SiO₂, 6.49 % Al₂O₃, 2.75 % Fe₂O₃): Kind's factor 0.92.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.