Worked example
Example: Duda Table 2.3 clinker (KS 0.92). The inputs, in the units selected above:
| Input | Value |
|---|---|
| CaO | 66.470 % |
| SiO₂ | 21.270 % |
| Al₂O₃ | 6.4900 % |
| Fe₂O₃ | 2.7500 % |
| MgO | 1.6900 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic modulus | 2.1786 |
| Silica ratio | 2.3019 |
| Alumina ratio | 2.3600 |
| Silicic acid ratio | 3.2773 |
| Lime standard I (Kühl) | 0.93321 |
| Lime saturation factor (Kühl II, British LSF) | 0.96331 |
| Lime saturation with MgO (up to 2 %) | 0.98168 |
| Kind's lime saturation factor | 0.92013 |
Open this example in the calculator and change any input.
Formula
\(LSF = \frac{C}{2.8S + 1.18A + 0.65F}, \quad SR = \frac{S}{A + F}, \quad AR = \frac{A}{F}, \quad HM = \frac{C}{S + A + F}, \quad KS_K = \frac{C - (1.65A + 0.35F)}{2.8S}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | CaO | - |
| \(S\) | SiO₂ | - |
| \(A\) | Al₂O₃ | - |
| \(F\) | Fe₂O₃ | - |
| \(M\) | MgO | - |
| \(HM\) | Hydraulic modulus | - |
| \(SR\) | Silica ratio | - |
| \(AR\) | Alumina ratio | - |
| \(S/A\) | Silicic acid ratio | - |
| \(KSt\,I\) | Lime standard I (Kühl) | - |
| \(LSF\) | Lime saturation factor (Kühl II, British LSF) | - |
| \(LSF_{MgO}\) | Lime saturation with MgO (up to 2 %) | - |
| \(KS_K\) | Kind's lime saturation factor | - |
Method and standards
Cement moduli.
Where it is used
- Raw mix control and kiln feed targets.
- Comparing clinker from different plants.
Common mistakes
- Using a raw meal analysis with loss on ignition for clinker moduli (ratios are unaffected, LSF too).
- Mixing the formulas from different standards.
Assumptions and limits
- Oxide analysis on the same basis.
References
- Duda
- Cement Data Book
- Vol. 1
- 3rd ed. (Bauverlag / Macdonald and Evans, 1985)
- secs. 1.7-1.8 (Kühl, Kind)
Questions and answers
Which LSF formula should I use?
Kühl's lime standard II (2.8 S + 1.18 A + 0.65 F) is the usual one and equals the British LSF; Kind's factor is used in Eastern Europe.
Why does the formula change below AR 0.64?
With little alumina all of it binds as ferrite, so the lime bound per unit Al₂O₃ and Fe₂O₃ changes.
What do the defaults represent?
The clinker of Duda's Table 2.3 (66.47 % CaO, 21.27 % SiO₂, 6.49 % Al₂O₃, 2.75 % Fe₂O₃): Kind's factor 0.92.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.