Worked example
Example: 10 m³ system, 870 kg/m³ cold, 700 hot, 60 % usable. The inputs, in the units selected above:
| Input | Value |
|---|---|
| System fluid volume when cold (heater, pipes, users) | 10.000 m³ |
| Thermic fluid | Enter the properties below |
| Cold filling temperature (for the fluid tables) | 30.000 °C |
| Maximum operating temperature (for the fluid tables) | 300.00 °C |
| Density at the cold filling temperature | 870.00 kg/m³ |
| Density at the maximum operating temperature | 700.00 kg/m³ |
| Share of the tank the expansion may fill | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Expansion tank volume | 4.0476 m³ |
| Expansion of the fluid | 2.4286 m³ |
| Volume expansion, share of cold volume | 24.286 % |
Open this example in the calculator and change any input.
Formula
\(e = \frac{\rho_c}{\rho_h} - 1 \qquad \Delta V = V\,e \qquad V_t = \frac{\Delta V}{f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | system fluid volume when cold | m³ |
| \(\text{fluid}\) | fluid chosen, or properties entered | – |
| \(T_c\) | cold filling temperature (tabulated fluids) | K |
| \(T_h\) | maximum operating temperature (tabulated fluids) | K |
| \(\rho_c\) | density at filling temperature | kg/m³ |
| \(\rho_h\) | density at maximum operating temperature | kg/m³ |
| \(f\) | share of the tank the expansion may fill | – |
| \(V_t\) | expansion tank volume | m³ |
| \(\Delta V\) | fluid expansion | m³ |
| \(e\) | volume expansion ratio | – |
Method and standards
Mass conservation: the fluid's mass is fixed, so its volume grows as density falls. Densities at the cold and hot temperatures. Fluid properties: either typed in, or taken from the makers' published liquid tables for Therminol 55 (Eastman bulletin TF8994), Therminol VP-1 (Eastman bulletin TF9141), DOWTHERM A (Dow technical data sheet; no kinematic viscosity tabulated) and Therminol 66 (Eastman bulletin SFE-HTF-19853), interpolated linearly between the published points (viscosity linearly in its logarithm) and never extrapolated. More fluids will be added as their makers' tables are captured.
Where it is used
- Sizing expansion tanks of hot oil systems.
- Checking an existing tank after the system is extended.
- Setting tank level alarms.
Common mistakes
- Using the heater volume only and forgetting pipes and users.
- Using a linear expansion coefficient over a wide temperature range.
- Leaving no room for the low-level reserve.
Assumptions and limits
- Whole system at the maximum temperature; no fluid loss.
- The tank volume covers the expansion only; the low-level reserve and vapour space must fit in the share f you choose (no minimum reserve is checked).
- With a tabulated fluid the temperatures are used and the typed densities ignored; with "enter the properties" the densities are used and the temperatures ignored.
References
- Mass conservation (volume change from density change)
Questions and answers
How much does thermic fluid expand?
By the ratio of its cold to hot density. A fluid at 870 kg/m³ cold and 700 kg/m³ hot expands 24.3 %; a 10 m³ system grows by 2.43 m³ and, using 60 % of the tank, needs a 4.05 m³ expansion tank.
What share of the tank can the expansion use?
The space between the cold filling level and the high-level alarm; the rest is the low-level reserve and vapour space. Your design rule or applicable code sets it; this calculator takes it as an input.
Should the tank be hot?
No. The expansion tank is kept cool (often by a cold seal leg) to slow oxidation of the oil in contact with air.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.