FireCADCalc

Turbine Overspeed after Load Rejection

Speed rise of a turbine-generator after load rejection from energy admitted while the valves close and from trapped steam, against the shaft inertia.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 200 MW unitIndustrial 30 MW back-pressureReheat 500 MW with large trapped volume

Accepted: 1 to 1,000,000 kg·m²
Accepted: 477.46 to 3,819.7 rpm
Accepted: 0.1 to 2,000 MW
Accepted: 0.01 to 5 s
Accepted: 0 to 100,000 kg
Accepted: 0 to 2,000 kJ/kg
Accepted: 30 to 100 %

Results

Energy into the rotor: P·t_c/2 while the valves close linearly, plus the trapped steam expanding in the turbine; ½J(ω₂² − ω₁²) equals their sum (losses and windage neglected, so it is conservative). Reheat units have large trapped volumes in reheaters and crossovers, hence intercept valves. Overspeed trips are usually set near 110 %.

Energy during valve closure87.500MJ
Energy from trapped steam420.00MJ
Kinetic energy at rated speed3,947.8MJ
Peak speed3,187.0rpm
Overspeed6.2333%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 200 MW unit. The inputs, in the units selected above:

InputValue
Shaft-line moment of inertia35,000 kg·m²
Rated speed3,000.0 rpm
Power before the rejection200.00 MW
Effective valve closing time0.30000 s
Steam trapped downstream of the valves400.00 kg
Usable enthalpy drop of trapped steam300.00 kJ/kg
Expansion efficiency75.000 %

Applying the formula below gives:

ResultValue
Energy during valve closure30.000 MJ
Energy from trapped steam90.000 MJ
Kinetic energy at rated speed1,727.2 MJ
Peak speed3,102.5 rpm
Overspeed3.4155 %

Open this example in the calculator and change any input.

Formula

\(E = \frac{Pt_c}{2} + m_{tr}\Delta h\eta, \quad \omega_{max} = \sqrt{\omega^2 + \frac{2E}{J}}\)

Variables

Symbol Meaning SI unit
\(J\) Shaft-line moment of inertia kg·m²
\(n\) Rated speed rad/s
\(P\) Power before the rejection W
\(t_c\) Effective valve closing time s
\(m_{tr}\) Steam trapped downstream of the valves kg
\(\Delta h\) Usable enthalpy drop of trapped steam J/kg
\(\eta\) Expansion efficiency -
\(E_v\) Energy during valve closure J
\(E_{tr}\) Energy from trapped steam J
\(E_0\) Kinetic energy at rated speed J
\(n_{max}\) Peak speed rad/s
\(n_{max}/n - 1\) Overspeed -

Method and standards

Overspeed.

Where it is used

  • Turbine protection reviews.
  • Effect of extraction non-return valves.

Common mistakes

  • Ignoring extraction line steam flowing back.
  • Using GD² without converting to J.

Assumptions and limits

  • No losses or windage; linear valve closure.

References

  • Rotor energy balance after load rejection

Questions and answers

Why does trapped steam matter?

Steam already past the stop and control valves keeps expanding through the turbine, driving the unloaded rotor faster.

How is overspeed limited?

Fast-closing stop, control and intercept valves, small trapped volumes and non-return valves on extractions.

What do the defaults represent?

An illustrative 200 MW unit at 3,000 rpm with J = 35,000 kg·m², 0.3 s effective closing time and 400 kg of trapped steam with 300 kJ/kg usable at 75 % efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Leizerovich, Steam Turbines for Modern Fossil-Fuel Power Plants (Fairmont Press, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.