FireCADCalc

Steam Turbine Power with up to Four Extractions and Condensing Exhaust

Shaft and generator power of an extraction-condensing turbine from inlet steam, up to four extractions (flow, pressure, temperature) and the exhaust (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 120 t/h at 105 bar(a) 535 C, four extractions, 0.1 bar(a) condenserSugar mill 60 t/h at 66 bar(a) 485 C, two extractions, exhaust dryness 0.91Back-pressure 40 t/h at 45 bar(a) 420 C, one extraction, exhaust 3 bar(a) at 165 C

Accepted: 0.036 to 7,200 t/h
Accepted: 1 to 300 bar
Accepted: 100 to 800 °C
Accepted: 0 to 3,600 t/h
Accepted: 0.01 to 300 bar
Accepted: 6.85 to 800 °C
Accepted: 0 to 3,600 t/h
Accepted: 0.01 to 300 bar
Accepted: 6.85 to 800 °C
Accepted: 0 to 3,600 t/h
Accepted: 0.01 to 300 bar
Accepted: 6.85 to 800 °C
Accepted: 0 to 3,600 t/h
Accepted: 0.01 to 300 bar
Accepted: 6.85 to 800 °C
Accepted: 5 to 100 %
Accepted: 0.01 to 200 bar
Accepted: 5 to 100 %
Accepted: 50 to 100 %
Accepted: 0.01 to 600 °C
Accepted: 5 to 100 %

Results

Each section carries the inlet flow less the extractions above it. Gland leakage, balance-drum leak-off and extractions used to heat feedwater are treated as ordinary extractions; enter them as extractions if significant.

Inlet enthalpy3,379.7kJ/kg
Extraction 1: enthalpy2,991.8kJ/kg
Extraction 1: temperature270.00°C
Extraction 1: dryness (1 = dry or superheated)1.0000
Section 1: isentropic efficiency (to extraction 1)71.422%
Section 1: shaft power (to extraction 1)6,465.4kW
Extraction 2: enthalpy2,783.9kJ/kg
Extraction 2: temperature158.90°C
Extraction 2: dryness (1 = dry or superheated)1.0000
Section 2: isentropic efficiency (to extraction 2)80.000%
Section 2: shaft power (to extraction 2)2,194.9kW
Exhaust (condensing) steam flow32.000t/h
Exhaust enthalpy2,375.8kJ/kg
Exhaust dryness (1 = dry or superheated)0.91000
Exhaust temperature49.420°C
Last-section isentropic efficiency86.018%
Last-section shaft power3,627.4kW
Total shaft power12,288kW
Generator output11,796kW
Specific steam consumption (inlet flow per generator output)5.0864kg/kWh
Condenser heat load19,279kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 120 t/h at 105 bar(a) 535 C, four extractions, 0.1 bar(a) condenser. The inputs, in the units selected above:

InputValue
Inlet (throttle) steam flow120.00 t/h
Inlet steam pressure (absolute)105.00 bar
Inlet steam temperature535.00 °C
Extraction 1: dataMeasured temperature (superheated)
Extraction 1: steam flow8.0000 t/h
Extraction 1: pressure (absolute)32.000 bar
Extraction 1: measured temperature371.12 °C
Extraction 2: dataMeasured temperature (superheated)
Extraction 2: steam flow25.000 t/h
Extraction 2: pressure (absolute)12.000 bar
Extraction 2: measured temperature258.77 °C
Extraction 3: dataMeasured temperature (superheated)
Extraction 3: steam flow15.000 t/h
Extraction 3: pressure (absolute)4.5000 bar
Extraction 3: measured temperature166.57 °C
Extraction 4: dataWet or not measured: from section efficiency
Extraction 4: steam flow5.0000 t/h
Extraction 4: pressure (absolute)1.5000 bar
Extraction 4: measured temperature111.37 °C
Section efficiency for extractions without a measured temperature82.000 %
Exhaust (condenser) pressure (absolute)0.10000 bar
Exhaust state fromLast-section efficiency
Last-section isentropic efficiency78.000 %
Exhaust dryness92.000 %
Measured exhaust temperature150.00 °C
Gearbox and generator efficiency96.500 %

Applying the formula below gives:

ResultValue
Inlet enthalpy3,459.0 kJ/kg
Extraction 1: enthalpy3,161.4 kJ/kg
Extraction 1: temperature371.12 °C
Extraction 1: dryness (1 = dry or superheated)1.0000
Section 1: isentropic efficiency (to extraction 1)82.002 %
Section 1: shaft power (to extraction 1)9,919.1 kW
Extraction 2: enthalpy2,955.5 kJ/kg
Extraction 2: temperature258.77 °C
Extraction 2: dryness (1 = dry or superheated)1.0000
Section 2: isentropic efficiency (to extraction 2)82.995 %
Section 2: shaft power (to extraction 2)6,405.2 kW
Extraction 3: enthalpy2,786.1 kJ/kg
Extraction 3: temperature166.57 °C
Extraction 3: dryness (1 = dry or superheated)1.0000
Section 3: isentropic efficiency (to extraction 3)82.000 %
Section 3: shaft power (to extraction 3)4,094.4 kW
Extraction 4: enthalpy2,625.4 kJ/kg
Extraction 4: temperature111.35 °C
Extraction 4: dryness (1 = dry or superheated)0.96959
Section 4: isentropic efficiency (to extraction 4)82.000 %
Section 4: shaft power (to extraction 4)3,213.0 kW
Exhaust (condensing) steam flow67.000 t/h
Exhaust enthalpy2,318.9 kJ/kg
Exhaust dryness (1 = dry or superheated)0.88921
Exhaust temperature45.808 °C
Last-section isentropic efficiency78.000 %
Last-section shaft power5,705.4 kW
Total shaft power29,337 kW
Generator output28,310 kW
Specific steam consumption (inlet flow per generator output)4.2387 kg/kWh
Condenser heat load39,587 kW

Open this example in the calculator and change any input.

Formula

\(P_{sh} = \sum_{j=1}^{n+1}\Big(\dot m_0 - \sum_{k<j}\dot m_k\Big)(h_{j-1} - h_j), \quad \dot m_{ex} = \dot m_0 - \sum_{k=1}^{n}\dot m_k\)

\(h_j = h(p_j, T_j)\ \text{(measured)} \ \text{or}\ h_j = h_{j-1} - \eta_w\left[h_{j-1} - h(p_j, s_{j-1})\right], \quad \eta_j = \frac{h_{j-1} - h_j}{h_{j-1} - h(p_j, s_{j-1})}, \quad P_{el} = \eta_gP_{sh}\)

Variables

Symbol Meaning SI unit
\(\dot m_0\) Inlet (throttle) steam flow kg/s
\(p_0\) Inlet steam pressure (absolute) Pa
\(T_0\) Inlet steam temperature K
\(\text{mode}_1\) Extraction 1: data -
\(\dot m_1\) Extraction 1: steam flow kg/s
\(p_1\) Extraction 1: pressure (absolute) Pa
\(T_1\) Extraction 1: measured temperature K
\(\text{mode}_2\) Extraction 2: data -
\(\dot m_2\) Extraction 2: steam flow kg/s
\(p_2\) Extraction 2: pressure (absolute) Pa
\(T_2\) Extraction 2: measured temperature K
\(\text{mode}_3\) Extraction 3: data -
\(\dot m_3\) Extraction 3: steam flow kg/s
\(p_3\) Extraction 3: pressure (absolute) Pa
\(T_3\) Extraction 3: measured temperature K
\(\text{mode}_4\) Extraction 4: data -
\(\dot m_4\) Extraction 4: steam flow kg/s
\(p_4\) Extraction 4: pressure (absolute) Pa
\(T_4\) Extraction 4: measured temperature K
\(\eta_w\) Section efficiency for extractions without a measured temperature -
\(p_{ex}\) Exhaust (condenser) pressure (absolute) Pa
\(\text{mode}_{ex}\) Exhaust state from -
\(\eta_{ex}\) Last-section isentropic efficiency -
\(x_{ex}\) Exhaust dryness -
\(T_{ex}\) Measured exhaust temperature K
\(\eta_g\) Gearbox and generator efficiency -
\(h_0\) Inlet enthalpy J/kg
\(h_1\) Extraction 1: enthalpy J/kg
\(T_1'\) Extraction 1: temperature K
\(x_1\) Extraction 1: dryness (1 = dry or superheated) -
\(\eta_{1}\) Section 1: isentropic efficiency (to extraction 1) -
\(P_1\) Section 1: shaft power (to extraction 1) W
\(h_2\) Extraction 2: enthalpy J/kg
\(T_2'\) Extraction 2: temperature K
\(x_2\) Extraction 2: dryness (1 = dry or superheated) -
\(\eta_{2}\) Section 2: isentropic efficiency (to extraction 2) -
\(P_2\) Section 2: shaft power (to extraction 2) W
\(h_3\) Extraction 3: enthalpy J/kg
\(T_3'\) Extraction 3: temperature K
\(x_3\) Extraction 3: dryness (1 = dry or superheated) -
\(\eta_{3}\) Section 3: isentropic efficiency (to extraction 3) -
\(P_3\) Section 3: shaft power (to extraction 3) W
\(h_4\) Extraction 4: enthalpy J/kg
\(T_4'\) Extraction 4: temperature K
\(x_4\) Extraction 4: dryness (1 = dry or superheated) -
\(\eta_{4}\) Section 4: isentropic efficiency (to extraction 4) -
\(P_4\) Section 4: shaft power (to extraction 4) W
\(\dot m_{ex}\) Exhaust (condensing) steam flow kg/s
\(h_{ex}\) Exhaust enthalpy J/kg
\(x_{ex}'\) Exhaust dryness (1 = dry or superheated) -
\(T_{ex}'\) Exhaust temperature K
\(\eta_{ex}'\) Last-section isentropic efficiency -
\(P_{ex}\) Last-section shaft power W
\(P_{sh}\) Total shaft power W
\(P_{el}\) Generator output W
\(SSC\) Specific steam consumption (inlet flow per generator output) kg/J
\(Q_c\) Condenser heat load W

Method and standards

Section-by-section heat balance of a multi-extraction steam turbine with IAPWS-IF97 steam properties.

Where it is used

  • Checking the output of extraction-condensing turbo-generators in sugar, paper, fertiliser and captive power plants.
  • Monitoring section efficiencies from extraction temperatures.
  • Planning extraction schedules and their effect on power.

Common mistakes

  • Using gauge pressures; all pressures must be absolute.
  • Entering a saturated temperature for a wet extraction; choose the efficiency option instead.
  • Listing extractions out of pressure order.
  • Forgetting gland and leak-off steam, which reduces the flow through the later sections.

Assumptions and limits

  • Steady state; each extraction point is treated as a single state; heat loss from the casing neglected.

Questions and answers

How is the power worked out?

Section by section: the steam between two extraction points does work equal to the flow through that section times its enthalpy drop. The first section carries the full inlet flow; each extraction removes its flow for the sections below it. The sum is the shaft power.

What if an extraction is wet?

Below saturation a pressure and temperature no longer fix the state, so for wet (or unmeasured) extractions the calculator expands from the previous point with the section efficiency you give. LP heater extractions in condensing turbines are often wet.

Why is the exhaust state needed separately?

The condenser steam is usually wet, so its temperature only tells you the pressure. Give either the last-section efficiency, the exhaust dryness, or, for a back-pressure machine, the measured superheated exhaust temperature.

What do the section efficiencies tell me?

Where extraction temperatures are measured, the efficiency of each section is computed. A section that falls in efficiency over time points to deposits or damage there; a value above 100 % means a temperature reading is wrong.

What do the defaults represent?

120 t/h at 105 bar(a) and 535 °C; extractions of 8 t/h at 32 bar(a) and 371 °C, 25 t/h at 12 bar(a) and 259 °C, 15 t/h at 4.5 bar(a) and 167 °C, and 5 t/h at 1.5 bar(a) (wet, 82 %); 67 t/h to a 0.1 bar(a) condenser at 78 %: about 29.3 MW at the shaft and 28.3 MW at the generator.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

IAPWS R7-97(2012) IF97 (steam properties), Steady-flow energy balance section by section (heat balance method, as in turbine acceptance testing)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.