Worked example
Example: 120 t/h at 105 bar(a) 535 C, four extractions, 0.1 bar(a) condenser. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet (throttle) steam flow | 120.00 t/h |
| Inlet steam pressure (absolute) | 105.00 bar |
| Inlet steam temperature | 535.00 °C |
| Extraction 1: data | Measured temperature (superheated) |
| Extraction 1: steam flow | 8.0000 t/h |
| Extraction 1: pressure (absolute) | 32.000 bar |
| Extraction 1: measured temperature | 371.12 °C |
| Extraction 2: data | Measured temperature (superheated) |
| Extraction 2: steam flow | 25.000 t/h |
| Extraction 2: pressure (absolute) | 12.000 bar |
| Extraction 2: measured temperature | 258.77 °C |
| Extraction 3: data | Measured temperature (superheated) |
| Extraction 3: steam flow | 15.000 t/h |
| Extraction 3: pressure (absolute) | 4.5000 bar |
| Extraction 3: measured temperature | 166.57 °C |
| Extraction 4: data | Wet or not measured: from section efficiency |
| Extraction 4: steam flow | 5.0000 t/h |
| Extraction 4: pressure (absolute) | 1.5000 bar |
| Extraction 4: measured temperature | 111.37 °C |
| Section efficiency for extractions without a measured temperature | 82.000 % |
| Exhaust (condenser) pressure (absolute) | 0.10000 bar |
| Exhaust state from | Last-section efficiency |
| Last-section isentropic efficiency | 78.000 % |
| Exhaust dryness | 92.000 % |
| Measured exhaust temperature | 150.00 °C |
| Gearbox and generator efficiency | 96.500 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inlet enthalpy | 3,459.0 kJ/kg |
| Extraction 1: enthalpy | 3,161.4 kJ/kg |
| Extraction 1: temperature | 371.12 °C |
| Extraction 1: dryness (1 = dry or superheated) | 1.0000 |
| Section 1: isentropic efficiency (to extraction 1) | 82.002 % |
| Section 1: shaft power (to extraction 1) | 9,919.1 kW |
| Extraction 2: enthalpy | 2,955.5 kJ/kg |
| Extraction 2: temperature | 258.77 °C |
| Extraction 2: dryness (1 = dry or superheated) | 1.0000 |
| Section 2: isentropic efficiency (to extraction 2) | 82.995 % |
| Section 2: shaft power (to extraction 2) | 6,405.2 kW |
| Extraction 3: enthalpy | 2,786.1 kJ/kg |
| Extraction 3: temperature | 166.57 °C |
| Extraction 3: dryness (1 = dry or superheated) | 1.0000 |
| Section 3: isentropic efficiency (to extraction 3) | 82.000 % |
| Section 3: shaft power (to extraction 3) | 4,094.4 kW |
| Extraction 4: enthalpy | 2,625.4 kJ/kg |
| Extraction 4: temperature | 111.35 °C |
| Extraction 4: dryness (1 = dry or superheated) | 0.96959 |
| Section 4: isentropic efficiency (to extraction 4) | 82.000 % |
| Section 4: shaft power (to extraction 4) | 3,213.0 kW |
| Exhaust (condensing) steam flow | 67.000 t/h |
| Exhaust enthalpy | 2,318.9 kJ/kg |
| Exhaust dryness (1 = dry or superheated) | 0.88921 |
| Exhaust temperature | 45.808 °C |
| Last-section isentropic efficiency | 78.000 % |
| Last-section shaft power | 5,705.4 kW |
| Total shaft power | 29,337 kW |
| Generator output | 28,310 kW |
| Specific steam consumption (inlet flow per generator output) | 4.2387 kg/kWh |
| Condenser heat load | 39,587 kW |
Open this example in the calculator and change any input.
Formula
\(P_{sh} = \sum_{j=1}^{n+1}\Big(\dot m_0 - \sum_{k<j}\dot m_k\Big)(h_{j-1} - h_j), \quad \dot m_{ex} = \dot m_0 - \sum_{k=1}^{n}\dot m_k\)
\(h_j = h(p_j, T_j)\ \text{(measured)} \ \text{or}\ h_j = h_{j-1} - \eta_w\left[h_{j-1} - h(p_j, s_{j-1})\right], \quad \eta_j = \frac{h_{j-1} - h_j}{h_{j-1} - h(p_j, s_{j-1})}, \quad P_{el} = \eta_gP_{sh}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_0\) | Inlet (throttle) steam flow | kg/s |
| \(p_0\) | Inlet steam pressure (absolute) | Pa |
| \(T_0\) | Inlet steam temperature | K |
| \(\text{mode}_1\) | Extraction 1: data | - |
| \(\dot m_1\) | Extraction 1: steam flow | kg/s |
| \(p_1\) | Extraction 1: pressure (absolute) | Pa |
| \(T_1\) | Extraction 1: measured temperature | K |
| \(\text{mode}_2\) | Extraction 2: data | - |
| \(\dot m_2\) | Extraction 2: steam flow | kg/s |
| \(p_2\) | Extraction 2: pressure (absolute) | Pa |
| \(T_2\) | Extraction 2: measured temperature | K |
| \(\text{mode}_3\) | Extraction 3: data | - |
| \(\dot m_3\) | Extraction 3: steam flow | kg/s |
| \(p_3\) | Extraction 3: pressure (absolute) | Pa |
| \(T_3\) | Extraction 3: measured temperature | K |
| \(\text{mode}_4\) | Extraction 4: data | - |
| \(\dot m_4\) | Extraction 4: steam flow | kg/s |
| \(p_4\) | Extraction 4: pressure (absolute) | Pa |
| \(T_4\) | Extraction 4: measured temperature | K |
| \(\eta_w\) | Section efficiency for extractions without a measured temperature | - |
| \(p_{ex}\) | Exhaust (condenser) pressure (absolute) | Pa |
| \(\text{mode}_{ex}\) | Exhaust state from | - |
| \(\eta_{ex}\) | Last-section isentropic efficiency | - |
| \(x_{ex}\) | Exhaust dryness | - |
| \(T_{ex}\) | Measured exhaust temperature | K |
| \(\eta_g\) | Gearbox and generator efficiency | - |
| \(h_0\) | Inlet enthalpy | J/kg |
| \(h_1\) | Extraction 1: enthalpy | J/kg |
| \(T_1'\) | Extraction 1: temperature | K |
| \(x_1\) | Extraction 1: dryness (1 = dry or superheated) | - |
| \(\eta_{1}\) | Section 1: isentropic efficiency (to extraction 1) | - |
| \(P_1\) | Section 1: shaft power (to extraction 1) | W |
| \(h_2\) | Extraction 2: enthalpy | J/kg |
| \(T_2'\) | Extraction 2: temperature | K |
| \(x_2\) | Extraction 2: dryness (1 = dry or superheated) | - |
| \(\eta_{2}\) | Section 2: isentropic efficiency (to extraction 2) | - |
| \(P_2\) | Section 2: shaft power (to extraction 2) | W |
| \(h_3\) | Extraction 3: enthalpy | J/kg |
| \(T_3'\) | Extraction 3: temperature | K |
| \(x_3\) | Extraction 3: dryness (1 = dry or superheated) | - |
| \(\eta_{3}\) | Section 3: isentropic efficiency (to extraction 3) | - |
| \(P_3\) | Section 3: shaft power (to extraction 3) | W |
| \(h_4\) | Extraction 4: enthalpy | J/kg |
| \(T_4'\) | Extraction 4: temperature | K |
| \(x_4\) | Extraction 4: dryness (1 = dry or superheated) | - |
| \(\eta_{4}\) | Section 4: isentropic efficiency (to extraction 4) | - |
| \(P_4\) | Section 4: shaft power (to extraction 4) | W |
| \(\dot m_{ex}\) | Exhaust (condensing) steam flow | kg/s |
| \(h_{ex}\) | Exhaust enthalpy | J/kg |
| \(x_{ex}'\) | Exhaust dryness (1 = dry or superheated) | - |
| \(T_{ex}'\) | Exhaust temperature | K |
| \(\eta_{ex}'\) | Last-section isentropic efficiency | - |
| \(P_{ex}\) | Last-section shaft power | W |
| \(P_{sh}\) | Total shaft power | W |
| \(P_{el}\) | Generator output | W |
| \(SSC\) | Specific steam consumption (inlet flow per generator output) | kg/J |
| \(Q_c\) | Condenser heat load | W |
Method and standards
Section-by-section heat balance of a multi-extraction steam turbine with IAPWS-IF97 steam properties.
Where it is used
- Checking the output of extraction-condensing turbo-generators in sugar, paper, fertiliser and captive power plants.
- Monitoring section efficiencies from extraction temperatures.
- Planning extraction schedules and their effect on power.
Common mistakes
- Using gauge pressures; all pressures must be absolute.
- Entering a saturated temperature for a wet extraction; choose the efficiency option instead.
- Listing extractions out of pressure order.
- Forgetting gland and leak-off steam, which reduces the flow through the later sections.
Assumptions and limits
- Steady state; each extraction point is treated as a single state; heat loss from the casing neglected.
Questions and answers
How is the power worked out?
Section by section: the steam between two extraction points does work equal to the flow through that section times its enthalpy drop. The first section carries the full inlet flow; each extraction removes its flow for the sections below it. The sum is the shaft power.
What if an extraction is wet?
Below saturation a pressure and temperature no longer fix the state, so for wet (or unmeasured) extractions the calculator expands from the previous point with the section efficiency you give. LP heater extractions in condensing turbines are often wet.
Why is the exhaust state needed separately?
The condenser steam is usually wet, so its temperature only tells you the pressure. Give either the last-section efficiency, the exhaust dryness, or, for a back-pressure machine, the measured superheated exhaust temperature.
What do the section efficiencies tell me?
Where extraction temperatures are measured, the efficiency of each section is computed. A section that falls in efficiency over time points to deposits or damage there; a value above 100 % means a temperature reading is wrong.
What do the defaults represent?
120 t/h at 105 bar(a) and 535 °C; extractions of 8 t/h at 32 bar(a) and 371 °C, 25 t/h at 12 bar(a) and 259 °C, 15 t/h at 4.5 bar(a) and 167 °C, and 5 t/h at 1.5 bar(a) (wet, 82 %); 67 t/h to a 0.1 bar(a) condenser at 78 %: about 29.3 MW at the shaft and 28.3 MW at the generator.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
IAPWS R7-97(2012) IF97 (steam properties), Steady-flow energy balance section by section (heat balance method, as in turbine acceptance testing)