Worked example
Example: 66 bar(a) 485 C, 20 t/h at 4 bar(a), 0.1 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Turbine inlet pressure (absolute) | 66.000 bar |
| Turbine inlet temperature | 485.00 °C |
| Extraction pressure (absolute) | 4.0000 bar |
| Condenser pressure (absolute) | 0.10000 bar |
| Efficiency, inlet to extraction | 80.000 % |
| Efficiency, extraction to condenser | 78.000 % |
| Gearbox and generator efficiency | 96.000 % |
| Process steam extracted | 20.000 t/h |
| Operating hours per year | 7,000.0 h |
| Value of electricity per kWh | 6.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Extraction steam enthalpy | 2,829.3 kJ/kg |
| Extraction steam temperature | 185.00 °C |
| Exhaust enthalpy | 2,378.0 kJ/kg |
| Power lost per t/h extracted | 120.35 kW |
| Power lost for the extraction | 2,407.0 kW |
| Energy lost per year | 16,849 MWh |
| Value of the energy lost per year | 1.0109e+08 |
| Process heat delivered per kWh given up (condensate returned saturated) | 5.1346 |
Open this example in the calculator and change any input.
Formula
\(e_t = \eta_g(h_x - h_c), \quad \Delta P_{el} = \dot m_x e_t, \quad \frac{q_x}{e_t} = \frac{h_x - h_{f,x}}{\eta_g(h_x - h_c)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_0\) | Turbine inlet pressure (absolute) | Pa |
| \(T_0\) | Turbine inlet temperature | K |
| \(p_x\) | Extraction pressure (absolute) | Pa |
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(\eta_{HP}\) | Efficiency, inlet to extraction | - |
| \(\eta_{LP}\) | Efficiency, extraction to condenser | - |
| \(\eta_g\) | Gearbox and generator efficiency | - |
| \(\dot m_x\) | Process steam extracted | kg/s |
| \(t_a\) | Operating hours per year | s |
| \(c_e\) | Value of electricity per kWh | - |
| \(h_x\) | Extraction steam enthalpy | J/kg |
| \(T_x\) | Extraction steam temperature | K |
| \(h_c\) | Exhaust enthalpy | J/kg |
| \(e_t\) | Power lost per t/h extracted | W |
| \(\Delta P_{el}\) | Power lost for the extraction | W |
| \(E_a\) | Energy lost per year | J |
| \(C_a\) | Value of the energy lost per year | - |
| \(q_x/e_t\) | Process heat delivered per kWh given up (condensate returned saturated) | - |
Method and standards
LP-section work foregone by extraction.
Where it is used
- Pricing process steam from cogeneration plants.
- Choosing extraction pressures.
- Comparing extraction with a separate process boiler.
Common mistakes
- Charging extraction steam at its full enthalpy value.
- Ignoring that the throttle flow may rise to restore power.
Assumptions and limits
- Constant throttle flow and section efficiencies; LP section has enough cooling flow.
Questions and answers
Why is the loss less than the enthalpy of the steam?
Extracting steam only gives up the work it would have done below the extraction point (h_x − h_c), not its heat; most of its heat still reaches the process.
Does extraction at a higher pressure cost more power?
Yes: the higher the extraction pressure, the more LP work each tonne would have done, so low-pressure process steam is cheaper to supply.
What do the defaults represent?
An illustrative case: 66 bar(a) 485 C, 20 t/h at 4 bar(a), 0.1 bar(a). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
IAPWS R7-97(2012) IF97 (steam properties), Steady-flow energy balance of the LP section