FireCADCalc

EV Battery Pack Sizing from Target Range

Gross pack energy for a target range from consumption, usable state-of-charge window and end-of-life capacity, and the cells in series and parallel to build it.

Inputs

Examples: Illustrative 400 km carCity car 200 km, LFP cellsElectric bus 250 km

Accepted: 10 to 2,000 km
Accepted: 100 to 500 Wh/km
Accepted: 50 to 100 %
Accepted: 60 to 100 %
Accepted: 12 to 1,000 V
Accepted: 1 to 5 V
Accepted: 0.1 to 277.78 Ah
Accepted: 0.01 to 10 kg
Accepted: 1 to 2.5

Results

Gross energy = range × consumption/(usable SOC window × end-of-life capacity); S = round(V_p/V_c), P = ⌈E_g/(S·V_c·C_c)⌉. The pack-to-cell mass factor covers modules, cooling, structure and electronics (about 1.3–1.6). Consumption should be the realistic (cold, highway) figure at the battery terminals.

Gross pack energy needed94.444kWh
Cells in series110.00
Cells in parallel4.0000
Pack energy as built96.360kWh
Total cells440.00
Pack mass574.20kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 400 km car. The inputs, in the units selected above:

InputValue
Target range at end of life400.00 km
Consumption at the battery170.00 Wh/km
Usable state-of-charge window90.000 %
End-of-life capacity80.000 %
Target nominal pack voltage400.00 V
Cell nominal voltage3.6500 V
Cell capacity60.000 Ah
Cell mass0.90000 kg
Pack-to-cell mass factor1.4500 -

Applying the formula below gives:

ResultValue
Gross pack energy needed94.444 kWh
Cells in series110.00
Cells in parallel4.0000
Pack energy as built96.360 kWh
Total cells440.00
Pack mass574.20 kg

Open this example in the calculator and change any input.

Formula

\(E_g = \frac{Re}{w_{SOC}SOH_{EOL}}, \quad S = \text{round}\frac{V_p}{V_c}, \quad P = \left\lceil\frac{E_g}{SV_cC_c}\right\rceil\)

Variables

Symbol Meaning SI unit
\(R\) Target range at end of life m
\(e\) Consumption at the battery J/m
\(w_{SOC}\) Usable state-of-charge window -
\(SOH_{EOL}\) End-of-life capacity -
\(V_p\) Target nominal pack voltage V
\(V_c\) Cell nominal voltage V
\(C_c\) Cell capacity C
\(m_c\) Cell mass kg
\(k_p\) Pack-to-cell mass factor -
\(E_g\) Gross pack energy needed J
\(S\) Cells in series -
\(P\) Cells in parallel -
\(E_{pack}\) Pack energy as built J
\(N\) Total cells -
\(m_{pack}\) Pack mass kg

Method and standards

Pack sizing.

Where it is used

  • EV and electric bus concept design.
  • Retrofit conversions.

Common mistakes

  • Using best-case consumption.
  • Forgetting end-of-life capacity.

Assumptions and limits

  • Nominal voltages; equal cells.

References

  • Pack energy and configuration balance

Questions and answers

Why size for end of life?

Capacity fades over years; sizing for 80 % SOH keeps the promised range for the warranty period.

Why not use 100 % of the battery?

Top and bottom states of charge are avoided to protect cells; usable windows are often 85–95 %.

What do the defaults represent?

An illustrative 400 km car at 170 Wh/km with 90 % usable window and 80 % end of life, 400 V pack of 3.65 V, 60 Ah, 0.9 kg cells.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bosch Automotive Handbook, 11th ed. (Robert Bosch GmbH / Wiley, 2022)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.