Worked example
Example: Illustrative 1800 kg car, 0-100 in 7.5 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vehicle mass | 1,800.0 kg |
| Rotating mass allowance | 5.0000 % |
| Target speed | 100.00 km/h |
| Target time | 7.5000 s |
| Top speed | 160.00 km/h |
| Rolling resistance coefficient | 0.009000 - |
| Drag area | 0.60000 m² |
| Air density | 1.2000 kg/m³ |
| Traction limit (μ × driven-axle share) | 0.60000 - |
| Rolling radius | 330.00 mm |
| Reduction gear ratio | 9.0000 - |
| Drivetrain efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Motor power for the acceleration | 131.86 kW |
| Motor power for top speed | 42.962 kW |
| Motor power needed | 131.86 kW |
| Motor torque for traction-limited launch | 431.49 N·m |
| Shortest time with traction limit only | 5.0778 s |
Open this example in the calculator and change any input.
Formula
\(t = \int_0^{v_k}\frac{m_e\,du}{F_{max} - R(u)} + \int_{v_k}^{v_t}\frac{m_e\,du}{P/u - R(u)}, \quad P_v = \frac{R(v_{max})v_{max}}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m\) | Vehicle mass | kg |
| \(\delta\) | Rotating mass allowance | - |
| \(v_t\) | Target speed | m/s |
| \(t_t\) | Target time | s |
| \(v_{max}\) | Top speed | m/s |
| \(f_r\) | Rolling resistance coefficient | - |
| \(C_dA\) | Drag area | m² |
| \(\rho\) | Air density | kg/m³ |
| \(\mu\) | Traction limit (μ × driven-axle share) | - |
| \(r\) | Rolling radius | m |
| \(i\) | Reduction gear ratio | - |
| \(\eta\) | Drivetrain efficiency | - |
| \(P_a\) | Motor power for the acceleration | W |
| \(P_v\) | Motor power for top speed | W |
| \(P\) | Motor power needed | W |
| \(T_m\) | Motor torque for traction-limited launch | N·m |
| \(t_{min}\) | Shortest time with traction limit only | s |
Method and standards
Acceleration power.
Where it is used
- EV motor and inverter sizing.
- Concept vehicle studies.
Common mistakes
- Ignoring traction limit at launch.
- Confusing peak and continuous power.
Assumptions and limits
- Level road; still air; ideal constant-power motor.
References
- Constant-force then constant-power acceleration
Questions and answers
Why is the launch traction-limited?
An electric motor delivers full torque from zero speed, so at low speed the tyres, not the motor, set the acceleration.
How much power for 0–100 in 7.5 s?
For an 1,800 kg car about 120–150 kW peak, depending on traction and drag.
What do the defaults represent?
An illustrative 1,800 kg car aiming at 0–100 km/h in 7.5 s and 160 km/h top speed, single 9:1 reduction, traction limit 0.6.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Wong, Theory of Ground Vehicles, 4th ed. (Wiley, 2008), ch. 3