FireCADCalc

EV Motor Power for an Acceleration Time and Top Speed

Motor power an electric vehicle needs for a 0–v acceleration time with a traction limit and road load, the power for its top speed, and the launch motor torque.

Inputs

Examples: Illustrative 1800 kg car, 0-100 in 7.5 sCity car 0-50 in 4 sVan 0-80 in 12 s

Accepted: 50 to 100,000 kg
Accepted: 0 to 30 %
Accepted: 3.6 to 288 km/h
Accepted: 1 to 120 s
Accepted: 18 to 360 km/h
Accepted: 0.002 to 0.05
Accepted: 0.1 to 20 m²
Accepted: 0.5 to 1.4 kg/m³
Accepted: 0.1 to 1.5
Accepted: 100 to 1,000 mm
Accepted: 1 to 20
Accepted: 50 to 100 %

Results

Constant wheel force (traction-limited) up to the speed where power takes over, then constant power, against rolling and aerodynamic load. Peak (short-time) motor power is what this gives; continuous rating for top speed and hills is lower.

Motor power for the acceleration131.86kW
Motor power for top speed42.962kW
Motor power needed131.86kW
Motor torque for traction-limited launch431.49N·m
Shortest time with traction limit only5.0778s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1800 kg car, 0-100 in 7.5 s. The inputs, in the units selected above:

InputValue
Vehicle mass1,800.0 kg
Rotating mass allowance5.0000 %
Target speed100.00 km/h
Target time7.5000 s
Top speed160.00 km/h
Rolling resistance coefficient0.009000 -
Drag area0.60000 m²
Air density1.2000 kg/m³
Traction limit (μ × driven-axle share)0.60000 -
Rolling radius330.00 mm
Reduction gear ratio9.0000 -
Drivetrain efficiency90.000 %

Applying the formula below gives:

ResultValue
Motor power for the acceleration131.86 kW
Motor power for top speed42.962 kW
Motor power needed131.86 kW
Motor torque for traction-limited launch431.49 N·m
Shortest time with traction limit only5.0778 s

Open this example in the calculator and change any input.

Formula

\(t = \int_0^{v_k}\frac{m_e\,du}{F_{max} - R(u)} + \int_{v_k}^{v_t}\frac{m_e\,du}{P/u - R(u)}, \quad P_v = \frac{R(v_{max})v_{max}}{\eta}\)

Variables

Symbol Meaning SI unit
\(m\) Vehicle mass kg
\(\delta\) Rotating mass allowance -
\(v_t\) Target speed m/s
\(t_t\) Target time s
\(v_{max}\) Top speed m/s
\(f_r\) Rolling resistance coefficient -
\(C_dA\) Drag area m²
\(\rho\) Air density kg/m³
\(\mu\) Traction limit (μ × driven-axle share) -
\(r\) Rolling radius m
\(i\) Reduction gear ratio -
\(\eta\) Drivetrain efficiency -
\(P_a\) Motor power for the acceleration W
\(P_v\) Motor power for top speed W
\(P\) Motor power needed W
\(T_m\) Motor torque for traction-limited launch N·m
\(t_{min}\) Shortest time with traction limit only s

Method and standards

Acceleration power.

Where it is used

  • EV motor and inverter sizing.
  • Concept vehicle studies.

Common mistakes

  • Ignoring traction limit at launch.
  • Confusing peak and continuous power.

Assumptions and limits

  • Level road; still air; ideal constant-power motor.

References

  • Constant-force then constant-power acceleration

Questions and answers

Why is the launch traction-limited?

An electric motor delivers full torque from zero speed, so at low speed the tyres, not the motor, set the acceleration.

How much power for 0–100 in 7.5 s?

For an 1,800 kg car about 120–150 kW peak, depending on traction and drag.

What do the defaults represent?

An illustrative 1,800 kg car aiming at 0–100 km/h in 7.5 s and 160 km/h top speed, single 9:1 reduction, traction limit 0.6.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Wong, Theory of Ground Vehicles, 4th ed. (Wiley, 2008), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.