Worked example
Example: Illustrative 150 kW 310 N m car at 80 km/h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Motor peak power | 150.00 kW |
| Motor peak torque | 310.00 N·m |
| Motor maximum speed | 16,000 rpm |
| Reduction gear ratio | 9.0000 - |
| Rolling radius | 330.00 mm |
| Drivetrain efficiency | 92.000 % |
| Vehicle mass | 1,800.0 kg |
| Rolling resistance coefficient | 0.010000 - |
| Speed of interest | 80.000 km/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Motor base speed | 4,620.6 rpm |
| Vehicle speed at base speed | 63.871 km/h |
| Speed at maximum motor speed | 221.17 km/h |
| Tractive force at the chosen speed | 6.2100 kN |
| Level acceleration at that speed (no drag) | 3.3519 m/s² |
| Maximum gradeability | 47.849 % |
Open this example in the calculator and change any input.
Formula
\(\omega_b = \frac{P_m}{T_m}, \quad F_x = \frac{T(\omega)i\eta}{r}, \quad F_0 = mg(\sin\theta + f\cos\theta)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_m\) | Motor peak power | W |
| \(T_m\) | Motor peak torque | N·m |
| \(n_{max}\) | Motor maximum speed | 1/s |
| \(i\) | Reduction gear ratio | - |
| \(r\) | Rolling radius | m |
| \(\eta\) | Drivetrain efficiency | - |
| \(m\) | Vehicle mass | kg |
| \(f_r\) | Rolling resistance coefficient | - |
| \(v\) | Speed of interest | m/s |
| \(n_b\) | Motor base speed | 1/s |
| \(v_b\) | Vehicle speed at base speed | m/s |
| \(v_{max}\) | Speed at maximum motor speed | m/s |
| \(F_x\) | Tractive force at the chosen speed | N |
| \(a\) | Level acceleration at that speed (no drag) | m/s² |
| \(G_{max}\) | Maximum gradeability | - |
Method and standards
Tractive envelope.
Where it is used
- EV drivetrain matching.
- Gradeability checks for vans and buses.
Common mistakes
- Using wheel speed instead of motor speed for base speed.
- Ignoring the motor speed limit.
Assumptions and limits
- Ideal constant-torque/constant-power motor.
References
- Electric drive tractive characteristic
Questions and answers
Why do EVs need only one gear?
Electric motors give full torque from standstill and run efficiently over a wide speed range, so one reduction covers launch and top speed.
What gradeability do cars need?
About 30 % at start-off for steep ramps; trucks and buses are specified separately.
What do the defaults represent?
An illustrative 1,800 kg car with a 150 kW, 310 N·m motor turning up to 16,000 rpm through a 9:1 reduction, checked at 80 km/h.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Wong, Theory of Ground Vehicles, 4th ed. (Wiley, 2008), ch. 3