Worked example
Example: Illustrative 250 A fast charge. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pack current (RMS over the duty) | 250.00 A |
| Pack internal resistance | 0.080000 Ω |
| Other heat into the loop (charger, electronics) | 1.5000 kW |
| Coolant specific heat | 3.5000 kJ/(kg·K) |
| Coolant density | 1,060.0 kg/m³ |
| Coolant temperature rise | 4.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Battery Joule heat | 5.0000 kW |
| Total heat to remove | 6.5000 kW |
| Coolant mass flow | 0.46429 kg/s |
| Coolant volume flow | 26.280 L/min |
Open this example in the calculator and change any input.
Formula
\(\dot Q = I^2R_{pack} + \dot Q_x, \quad \dot m = \frac{\dot Q}{c_p\Delta T}, \quad \dot V = \frac{\dot m}{\rho}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I\) | Pack current (RMS over the duty) | A |
| \(R_{pack}\) | Pack internal resistance | Ω |
| \(\dot Q_x\) | Other heat into the loop (charger, electronics) | W |
| \(c_p\) | Coolant specific heat | J/(kg·K) |
| \(\rho\) | Coolant density | kg/m³ |
| \(\Delta T\) | Coolant temperature rise | K |
| \(\dot Q_b\) | Battery Joule heat | W |
| \(\dot Q\) | Total heat to remove | W |
| \(\dot m\) | Coolant mass flow | kg/s |
| \(\dot V\) | Coolant volume flow | m³/s |
Method and standards
Coolant flow.
Where it is used
- Sizing pack cooling pumps and chillers.
- Checking fast-charge thermal limits.
Common mistakes
- Using the cell resistance instead of the pack resistance.
- Using water's c_p for glycol.
Assumptions and limits
- Steady state; reversible heat neglected; uniform resistance.
References
- Joule heating and coolant heat balance
Questions and answers
Which current should I use?
The RMS current over a representative duty, such as a fast charge or a hill climb; heat goes with the square of current.
Why keep the coolant rise small?
Cell temperature differences cause uneven ageing; packs aim for a few kelvin across the pack.
What do the defaults represent?
An illustrative 250 A fast charge through a 0.08 Ω pack with 1.5 kW from the charger, glycol coolant rising 4 K.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Bosch Automotive Handbook, 11th ed. (Robert Bosch GmbH / Wiley, 2022)