Worked example
Example: Illustrative 400 km car. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Target range at end of life | 400.00 km |
| Consumption at the battery | 170.00 Wh/km |
| Usable state-of-charge window | 90.000 % |
| End-of-life capacity | 80.000 % |
| Target nominal pack voltage | 400.00 V |
| Cell nominal voltage | 3.6500 V |
| Cell capacity | 60.000 Ah |
| Cell mass | 0.90000 kg |
| Pack-to-cell mass factor | 1.4500 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gross pack energy needed | 94.444 kWh |
| Cells in series | 110.00 |
| Cells in parallel | 4.0000 |
| Pack energy as built | 96.360 kWh |
| Total cells | 440.00 |
| Pack mass | 574.20 kg |
Open this example in the calculator and change any input.
Formula
\(E_g = \frac{Re}{w_{SOC}SOH_{EOL}}, \quad S = \text{round}\frac{V_p}{V_c}, \quad P = \left\lceil\frac{E_g}{SV_cC_c}\right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(R\) | Target range at end of life | m |
| \(e\) | Consumption at the battery | J/m |
| \(w_{SOC}\) | Usable state-of-charge window | - |
| \(SOH_{EOL}\) | End-of-life capacity | - |
| \(V_p\) | Target nominal pack voltage | V |
| \(V_c\) | Cell nominal voltage | V |
| \(C_c\) | Cell capacity | C |
| \(m_c\) | Cell mass | kg |
| \(k_p\) | Pack-to-cell mass factor | - |
| \(E_g\) | Gross pack energy needed | J |
| \(S\) | Cells in series | - |
| \(P\) | Cells in parallel | - |
| \(E_{pack}\) | Pack energy as built | J |
| \(N\) | Total cells | - |
| \(m_{pack}\) | Pack mass | kg |
Method and standards
Pack sizing.
Where it is used
- EV and electric bus concept design.
- Retrofit conversions.
Common mistakes
- Using best-case consumption.
- Forgetting end-of-life capacity.
Assumptions and limits
- Nominal voltages; equal cells.
References
- Pack energy and configuration balance
Questions and answers
Why size for end of life?
Capacity fades over years; sizing for 80 % SOH keeps the promised range for the warranty period.
Why not use 100 % of the battery?
Top and bottom states of charge are avoided to protect cells; usable windows are often 85–95 %.
What do the defaults represent?
An illustrative 400 km car at 170 Wh/km with 90 % usable window and 80 % end of life, 400 V pack of 3.65 V, 60 Ah, 0.9 kg cells.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Bosch Automotive Handbook, 11th ed. (Robert Bosch GmbH / Wiley, 2022)