FireCADCalc

EV Charging Time with Constant-Current and Taper Phases

Charging time of a battery in a constant-current phase to a switch-over state of charge and an exponential constant-voltage taper to a cut-off current.

Inputs

Examples: Illustrative 150 Ah pack at 2C to 80 %Home charger 1C to 90 %Fast charge 3C to 70 %

Accepted: 1 to 2,777.8 Ah
Accepted: 0 to 95 %
Accepted: 30 to 99 %
Accepted: 0.1 to 2,000 A
Accepted: 0.01 to 500 A

Results

CC: t = Q(SOC_cv − SOC₀)/I. CV: current decays as I₀e^(−t/τ); the remaining charge Q(1 − SOC_cv) = τ(I₀ − I_end) fixes τ, and the taper ends at t = τ·ln(I₀/I_end). The taper is why the last 20 % takes as long as the first 70 % at a fast charger. Real chargers also limit power by cell temperature.

Constant-current time262.50min
Taper time constant40.000min
Constant-voltage time110.90min
Total charging time373.40min
Charge rate in the CC phase0.16000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 150 Ah pack at 2C to 80 %. The inputs, in the units selected above:

InputValue
Battery capacity150.00 Ah
Starting state of charge10.000 %
State of charge at switch to constant voltage80.000 %
Constant-current charge current300.00 A
Cut-off current10.000 A

Applying the formula below gives:

ResultValue
Constant-current time21.000 min
Taper time constant6.2069 min
Constant-voltage time21.111 min
Total charging time42.111 min
Charge rate in the CC phase2.0000

Open this example in the calculator and change any input.

Formula

\(t_{cc} = \frac{Q(SOC_{cv} - SOC_0)}{I_{cc}}, \quad \tau = \frac{Q(1 - SOC_{cv})}{I_{cc} - I_{end}}, \quad t_{cv} = \tau\ln\frac{I_{cc}}{I_{end}}\)

Variables

Symbol Meaning SI unit
\(Q\) Battery capacity C
\(SOC_0\) Starting state of charge -
\(SOC_{cv}\) State of charge at switch to constant voltage -
\(I_{cc}\) Constant-current charge current A
\(I_{end}\) Cut-off current A
\(t_{cc}\) Constant-current time s
\(\tau\) Taper time constant s
\(t_{cv}\) Constant-voltage time s
\(t\) Total charging time s
\(C\) Charge rate in the CC phase -

Method and standards

Charge time.

Where it is used

  • Fleet charging schedules.
  • Comparing 80 % and 100 % charging.

Common mistakes

  • Assuming constant current to 100 %.
  • Mixing pack and cell capacity.

Assumptions and limits

  • Exponential taper; constant CC current; no thermal limits.

References

  • CC–CV charging with exponential taper

Questions and answers

Why does charging slow above 80 %?

Cell voltage reaches its limit, so the charger holds voltage and current falls as the cells fill.

Is the taper really exponential?

Approximately; the real curve depends on cell resistance and diffusion, but the exponential captures the long tail.

What do the defaults represent?

An illustrative 150 Ah pack charged from 10 % at 300 A (2C) to 80 %, then tapered to 10 A.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ehsani, Gao, Longo and Ebrahimi, Modern Electric, Hybrid Electric and Fuel Cell Vehicles, 3rd ed. (CRC, 2018)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.