Worked example
Example: Illustrative 150 Ah pack at 2C to 80 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Battery capacity | 150.00 Ah |
| Starting state of charge | 10.000 % |
| State of charge at switch to constant voltage | 80.000 % |
| Constant-current charge current | 300.00 A |
| Cut-off current | 10.000 A |
Applying the formula below gives:
| Result | Value |
|---|---|
| Constant-current time | 21.000 min |
| Taper time constant | 6.2069 min |
| Constant-voltage time | 21.111 min |
| Total charging time | 42.111 min |
| Charge rate in the CC phase | 2.0000 |
Open this example in the calculator and change any input.
Formula
\(t_{cc} = \frac{Q(SOC_{cv} - SOC_0)}{I_{cc}}, \quad \tau = \frac{Q(1 - SOC_{cv})}{I_{cc} - I_{end}}, \quad t_{cv} = \tau\ln\frac{I_{cc}}{I_{end}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Battery capacity | C |
| \(SOC_0\) | Starting state of charge | - |
| \(SOC_{cv}\) | State of charge at switch to constant voltage | - |
| \(I_{cc}\) | Constant-current charge current | A |
| \(I_{end}\) | Cut-off current | A |
| \(t_{cc}\) | Constant-current time | s |
| \(\tau\) | Taper time constant | s |
| \(t_{cv}\) | Constant-voltage time | s |
| \(t\) | Total charging time | s |
| \(C\) | Charge rate in the CC phase | - |
Method and standards
Charge time.
Where it is used
- Fleet charging schedules.
- Comparing 80 % and 100 % charging.
Common mistakes
- Assuming constant current to 100 %.
- Mixing pack and cell capacity.
Assumptions and limits
- Exponential taper; constant CC current; no thermal limits.
References
- CC–CV charging with exponential taper
Questions and answers
Why does charging slow above 80 %?
Cell voltage reaches its limit, so the charger holds voltage and current falls as the cells fill.
Is the taper really exponential?
Approximately; the real curve depends on cell resistance and diffusion, but the exponential captures the long tail.
What do the defaults represent?
An illustrative 150 Ah pack charged from 10 % at 300 A (2C) to 80 %, then tapered to 10 A.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Ehsani, Gao, Longo and Ebrahimi, Modern Electric, Hybrid Electric and Fuel Cell Vehicles, 3rd ed. (CRC, 2018)