FireCADCalc

Diffuser vs Milling Tandem: Power and Steam

Power saved by a diffuser station over a milling tandem per tonne fibre, the steam that power takes at a turbine rate, and the extra heating steam of the diffuser.

Sugar mill and cogenerationSteam turbine

Inputs

Examples: South African figuresTurbo-generator rate

Hugot (South Africa): 188 kWh/t fibre, 82 for preparation and 106 for the tandem.
Hugot (South Africa): 125 kWh/t fibre including preparation and dewatering.
Hugot: about 15 kg/kWh for mill and shredder turbines, 11 for the turbo-generator.

Results

Hugot also reports slightly more molasses and sucrose loss with diffusers (about 0.7 kg sucrose per t cane in one comparison).

Power saved by the diffuser1,050.0kW
Steam saved on the drives11.550t/h
Extra heating steam4.0000t/h
Net steam saved (negative: diffuser uses more)7.5500t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: South African figures. The inputs, in the units selected above:

InputValue
Crushing rate250.00 t/h
Fibre % cane14.500 %
Milling station energy per tonne fibre188.00 kWh/t
Diffusion station energy per tonne fibre125.00 kWh/t
Steam rate of the drives or turbo-generator15.000 kg/kWh
Extra heating steam of the diffuser per tonne cane30.000 kg/t

Applying the formula below gives:

ResultValue
Power saved by the diffuser2,283.8 kW
Steam saved on the drives34.256 t/h
Extra heating steam7.5000 t/h
Net steam saved (negative: diffuser uses more)26.756 t/h

Open this example in the calculator and change any input.

Formula

\(\Delta P = (e_m - e_d)A f, \quad \Delta\dot m_P = SR\,\Delta P, \quad \Delta\dot m_H = s_x A, \quad \Delta\dot m = \Delta\dot m_P - \Delta\dot m_H\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(e_m\) Milling station energy per tonne fibre J/kg
\(e_d\) Diffusion station energy per tonne fibre J/kg
\(SR\) Steam rate of the drives or turbo-generator kg/J
\(s_x\) Extra heating steam of the diffuser per tonne cane kg/kg
\(\Delta P\) Power saved by the diffuser W
\(\Delta\dot m_P\) Steam saved on the drives kg/s
\(\Delta\dot m_H\) Extra heating steam kg/s
\(\Delta\dot m\) Net steam saved (negative: diffuser uses more) kg/s

Method and standards

Energy comparison on the fibre rate.

Where it is used

  • Choosing between milling and diffusion.
  • Cogeneration studies.

Common mistakes

  • Comparing installed with absorbed power.
  • Ignoring that heating steam can be exhaust.

Assumptions and limits

  • Station energies from one survey; use plant data where possible.
  • The net figure subtracts low-pressure heating steam from live drive steam by mass. It is not an energy or fuel balance: drive-turbine exhaust may itself supply process heat, so a positive net saving does not by itself mean less fuel.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 14 (station energies, p. 240) and ch. 23 (comparison, p. 398)

Questions and answers

Does a diffuser save energy?

It needs less mechanical power but more heat; the balance depends on how the power is made and whether exhaust is in surplus.

Why per tonne fibre?

Mill and preparation work depend on the fibre passing.

Other differences?

Diffusers usually give higher extraction but slightly more molasses and colour; mills handle dirty cane better.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.