FireCADCalc

Diffuser Extraction by Counter-Current Theory

Extraction of a counter-current diffuser from the draft ratio and the number of transfer units (Hugot eqn 23.12), and overall extraction with a mill ahead of it.

Sugar mill and cogeneration

Inputs

Examples: Cane diffuser, draft 1.1Bagasse diffuser after a 70 % mill

Results

Hugot: a bagasse diffuser after a mill extracting 70 % that extracts 97 % of the rest gives 99 % overall.

Sugar left per sugar entering3.0290%
Diffuser extraction96.971%
Overall extraction96.971%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Cane diffuser, draft 1.1. The inputs, in the units selected above:

InputValue
Draft ratio (juice drawn per juice entering with the solids)1.1000 -
Transfer units ΔL of the diffuser15.000 -
Extraction of a mill ahead of the diffuser (0 for a cane diffuser)0 %

Applying the formula below gives:

ResultValue
Sugar left per sugar entering3.0290 %
Diffuser extraction96.971 %
Overall extraction96.971 %

Open this example in the calculator and change any input.

Formula

\(\frac{\varepsilon}{Z_0} = \frac{(q - 1)e^{-(q-1)N/q}}{q - e^{-(q-1)N/q}}, \quad E_d = 1 - \frac{\varepsilon}{Z_0}, \quad E = e_m + (1 - e_m)E_d\)

Variables

Symbol Meaning SI unit
\(q\) Draft ratio (juice drawn per juice entering with the solids) -
\(N\) Transfer units ΔL of the diffuser -
\(e_m\) Extraction of a mill ahead of the diffuser (0 for a cane diffuser) -
\(\varepsilon/Z_0\) Sugar left per sugar entering -
\(E_d\) Diffuser extraction -
\(E\) Overall extraction -

Method and standards

Hugot's counter-current diffusion theory.

Where it is used

  • Judging the effect of draft on extraction.
  • Comparing cane and bagasse diffusion.

Common mistakes

  • Using draft on cane where draft on juice is meant.
  • Expecting the theory to give absolute values without calibration.

Assumptions and limits

  • Ideal counter-current stages; calibrate N from plant results (it has no direct physical input).
  • Draft here is Hugot's theoretical ratio, juice drawn per juice entering with the solids. The diffuser draft balance calculator uses draft per cane (draft juice % cane); the two are not the same number.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 23
  • counter-current theory
  • eqns 23.5–23.12
  • pp. 361–366
  • and p. 368

Questions and answers

What is draft?

The weight of juice drawn from the diffuser per weight of juice entering with the cane; it must exceed 1 for counter-current extraction to work.

Why does extraction rise steeply with draft near 1?

With little excess liquid, the last stages see almost no concentration difference to drive diffusion.

What are transfer units?

A measure of the contact the diffuser gives (Hugot's ΔL): longer beds, slower travel and better preparation raise it.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.