Worked example
Example: South African figures. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Fibre % cane | 14.500 % |
| Milling station energy per tonne fibre | 188.00 kWh/t |
| Diffusion station energy per tonne fibre | 125.00 kWh/t |
| Steam rate of the drives or turbo-generator | 15.000 kg/kWh |
| Extra heating steam of the diffuser per tonne cane | 30.000 kg/t |
Applying the formula below gives:
| Result | Value |
|---|---|
| Power saved by the diffuser | 2,283.8 kW |
| Steam saved on the drives | 34.256 t/h |
| Extra heating steam | 7.5000 t/h |
| Net steam saved (negative: diffuser uses more) | 26.756 t/h |
Open this example in the calculator and change any input.
Formula
\(\Delta P = (e_m - e_d)A f, \quad \Delta\dot m_P = SR\,\Delta P, \quad \Delta\dot m_H = s_x A, \quad \Delta\dot m = \Delta\dot m_P - \Delta\dot m_H\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(f\) | Fibre % cane | - |
| \(e_m\) | Milling station energy per tonne fibre | J/kg |
| \(e_d\) | Diffusion station energy per tonne fibre | J/kg |
| \(SR\) | Steam rate of the drives or turbo-generator | kg/J |
| \(s_x\) | Extra heating steam of the diffuser per tonne cane | kg/kg |
| \(\Delta P\) | Power saved by the diffuser | W |
| \(\Delta\dot m_P\) | Steam saved on the drives | kg/s |
| \(\Delta\dot m_H\) | Extra heating steam | kg/s |
| \(\Delta\dot m\) | Net steam saved (negative: diffuser uses more) | kg/s |
Method and standards
Energy comparison on the fibre rate.
Where it is used
- Choosing between milling and diffusion.
- Cogeneration studies.
Common mistakes
- Comparing installed with absorbed power.
- Ignoring that heating steam can be exhaust.
Assumptions and limits
- Station energies from one survey; use plant data where possible.
- The net figure subtracts low-pressure heating steam from live drive steam by mass. It is not an energy or fuel balance: drive-turbine exhaust may itself supply process heat, so a positive net saving does not by itself mean less fuel.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 14 (station energies, p. 240) and ch. 23 (comparison, p. 398)
Questions and answers
Does a diffuser save energy?
It needs less mechanical power but more heat; the balance depends on how the power is made and whether exhaust is in surplus.
Why per tonne fibre?
Mill and preparation work depend on the fibre passing.
Other differences?
Diffusers usually give higher extraction but slightly more molasses and colour; mills handle dirty cane better.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.