FireCADCalc

Reduced Boiling-House Recovery (Gundu Rao, Hugot)

Boiling-house recovery reduced to 85 juice purity by Gundu Rao, Hugot's true-purity form and his 115 approximation (eqns 39.14–39.17), and general reduced recovery.

Sugar mill and cogeneration

Inputs

Examples: Hugot exampleLow purity juice

Results

Hugot's example: r_g 90, q 100, y 3, M 38, B_m 85, DS 81.6, J 88, B_j 14, M′ 45 gives 87.37 (true purity) and 87.34 (factor 115).

Gundu Rao (eqn 39.14)87.542%
With true purity and dry solids (39.15)87.370%
Approximate, factor 115 (39.16)87.340%
Share of juice non-sucrose left in final molasses80.143%
General reduced recovery e₁₂.₅ r″₈₅ (39.17, with the factor-115 form)82.973%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example. The inputs, in the units selected above:

InputValue
Actual boiling-house recovery ESG90.000 %
Gravity purity of mixed juice88.000 %
Gravity purity of final molasses38.000 %
True purity of final molasses45.000 %
Final molasses % cane3.0000 %
Dry solids % final molasses81.600 %
Refractometric brix of final molasses85.000 %
Mixed juice % cane100.00 %
Refractometric brix of mixed juice14.000 %
Reduced extraction95.000 %

Applying the formula below gives:

ResultValue
Gundu Rao (eqn 39.14)87.542 %
With true purity and dry solids (39.15)87.370 %
Approximate, factor 115 (39.16)87.340 %
Share of juice non-sucrose left in final molasses80.143 %
General reduced recovery e₁₂.₅ r″₈₅ (39.17, with the factor-115 form)82.973 %

Open this example in the calculator and change any input.

Formula

\(r_{85} = r_g + \frac{100M}{100 - M}\cdot\frac{85 - J}{0.85J}\)

\(r'_{85} = r_g + \frac{100M'(85 - J)\,y\,DS_m}{0.85J(100 - J)\,q B_j}, \quad r''_{85} = r_g + \frac{115M(85 - J)\,y B_m}{0.85J(100 - J)\,q B_j}, \quad R = e_{12.5}\,r''_{85}\)

Variables

Symbol Meaning SI unit
\(r_g\) Actual boiling-house recovery ESG -
\(J\) Gravity purity of mixed juice -
\(M\) Gravity purity of final molasses -
\(M'\) True purity of final molasses -
\(y\) Final molasses % cane -
\(DS_m\) Dry solids % final molasses -
\(B_m\) Refractometric brix of final molasses -
\(q\) Mixed juice % cane -
\(B_j\) Refractometric brix of mixed juice -
\(e_{12.5}\) Reduced extraction -
\(r_{85}\) Gundu Rao (eqn 39.14) -
\(r'_{85}\) With true purity and dry solids (39.15) -
\(r''_{85}\) Approximate, factor 115 (39.16) -
\(\lambda\) Share of juice non-sucrose left in final molasses -
\(R\) General reduced recovery e₁₂.₅ r₈₅ (39.17) -

Method and standards

Gundu Rao's formula and Hugot's corrections.

Where it is used

  • Comparing factories with different juice.
  • Season reports.

Common mistakes

  • Mixing refractometric and gravity values.
  • Using recovery without ESG.

Assumptions and limits

  • Percent forms as in Hugot; fractions at the interface.
  • The general reduced recovery R uses r″₈₅, the factor-115 form.
  • Molasses purity must be below juice purity; a note flags a true molasses purity below the gravity purity.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 39
  • eqns 39.14–39.17 and example
  • pp. 844–846

Questions and answers

What does Gundu Rao change?

Only the loss in final molasses depends on juice purity, so only that loss is reduced to 85 purity; other losses stay as they are.

Why use true purity and dry solids?

Gravity purity and refractometric brix of molasses differ from the true values; Hugot's form uses the real non-sucrose in molasses.

What is λ?

The share of the juice's non-sucrose that ends in final molasses, about 0.8 in defecation factories.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.