Worked example
Example: Illustrative empty 12 x 14 m tank. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tank diameter | 12.000 m |
| Tank height | 14.000 m |
| Empty mass (shell, roof, bottom) | 45.000 t |
| Design wind speed | 45.000 m/s |
| Force coefficient | 0.70000 - |
| Air density | 1.2250 kg/m³ |
| Base friction coefficient | 0.40000 - |
| Anchor bolts | 24.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Wind pressure | 1.2403 kPa |
| Wind force | 145.86 kN |
| Overturning moment | 1,021.0 kN·m |
| Overturning factor of safety | 2.5933 |
| Sliding factor of safety | 1.2102 |
| Anchor bolt tension (each) | 0 kN |
Open this example in the calculator and change any input.
Formula
\(F = \tfrac12\rho v^2C_fDH, \quad FS_o = \frac{mgD/2}{FH/2}, \quad T_b = \frac{4M_o}{n_bD} - \frac{mg}{n_b}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Tank diameter | m |
| \(H\) | Tank height | m |
| \(m\) | Empty mass (shell, roof, bottom) | kg |
| \(v\) | Design wind speed | m/s |
| \(C_f\) | Force coefficient | - |
| \(\rho\) | Air density | kg/m³ |
| \(\mu\) | Base friction coefficient | - |
| \(n_b\) | Anchor bolts | - |
| \(q\) | Wind pressure | Pa |
| \(F\) | Wind force | N |
| \(M_o\) | Overturning moment | N·m |
| \(FS_o\) | Overturning factor of safety | - |
| \(FS_s\) | Sliding factor of safety | - |
| \(T_b\) | Anchor bolt tension (each) | N |
Method and standards
Tank stability.
Where it is used
- Tank anchoring design.
- Construction stage checks.
Common mistakes
- Using the full tank weight.
- Ignoring internal vacuum or pressure uplift.
Assumptions and limits
- Uniform wind on the projected area; rigid tank.
References
- Rigid-body stability of a vertical tank under wind
- Megyesy
- Pressure Vessel Handbook (Pressure Vessel Publishing)
Questions and answers
Why check the tank empty?
An empty tank is lightest, so its resistance to overturning and sliding is smallest.
When are anchors needed?
When the overturning factor of safety drops below about 1.5, typically tall, slender, light tanks.
What do the defaults represent?
An illustrative empty 12 m diameter, 14 m tall tank weighing 45 t in a 45 m/s wind, 24 anchor bolts.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.