Worked example
Example: Illustrative 1000 m3 gasoline-like fills. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Liquid volume filled | 1,000.0 m³ |
| True vapour pressure at storage temperature | 30.000 kPa |
| Vapour molar mass | 66.000 kg/kmol |
| Vapour space temperature | 25.000 °C |
| Vapour saturation factor | 80.000 % |
| Fills per year | 30.000 - |
| Vapour recovery efficiency | 0 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour concentration in the displaced gas | 0.63898 kg/m³ |
| Vapour lost per fill | 638.98 kg |
| Vapour lost per year | 19.169 t |
Open this example in the calculator and change any input.
Formula
\(c_v = \frac{K_sp_vM}{RT}, \quad m = V_fc_v(1 - \eta_r)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_f\) | Liquid volume filled | m³ |
| \(p_v\) | True vapour pressure at storage temperature | Pa |
| \(M\) | Vapour molar mass | kg/kmol |
| \(T\) | Vapour space temperature | K |
| \(K_s\) | Vapour saturation factor | - |
| \(N\) | Fills per year | - |
| \(\eta_r\) | Vapour recovery efficiency | - |
| \(c_v\) | Vapour concentration in the displaced gas | kg/m³ |
| \(m_1\) | Vapour lost per fill | kg |
| \(m_y\) | Vapour lost per year | kg |
Method and standards
Displacement loss.
Where it is used
- Emission estimates and vapour recovery business cases.
- Product loss accounting.
Common mistakes
- Using Reid vapour pressure as true vapour pressure.
- Forgetting breathing losses.
Assumptions and limits
- Ideal gas; uniform vapour concentration.
References
- Ideal-gas vapour content of displaced tank gas
Questions and answers
Why do tanks lose product when filled?
Incoming liquid pushes out the gas above it, which is nearly saturated with product vapour.
How can losses be cut?
Vapour balancing or recovery units, internal floating roofs, and filling at lower temperatures.
What do the defaults represent?
An illustrative fixed-roof tank receiving 1,000 m³ of light gasoline-like product (30 kPa vapour pressure, M = 66) 30 times a year at 25 °C, vapour 80 % saturated.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Perry's Chemical Engineers' Handbook (McGraw-Hill)