FireCADCalc

Pressure Vessel Empty, Operating and Hydrotest Weight

Empty, operating and water-full (hydrotest) weight of a cylindrical vessel with 2:1 ellipsoidal or hemispherical heads, from its size, thicknesses and densities.

Inputs

Examples: Illustrative 2 m x 6 m, 2:1 headsHemispherical 1.2 m x 4 mStainless 0.8 m x 3 m

Accepted: 100 to 20,000 mm
Accepted: 0.1 to 100 m
Accepted: 1 to 300 mm
Accepted: 1 to 300 mm
Accepted: 1,000 to 20,000 kg/m³
Accepted: 0 to 100 %
Accepted: 1 to 3,000 kg/m³
Accepted: 0 to 100 %

Results

Shell on its mean diameter; head surface ≈ 1.084D² for 2:1 ellipsoidal and πD²/2 for hemispherical heads; head volumes πD³/24 and πD³/12. The allowance covers nozzles, flanges, skirt or saddles and internals; use the vendor drawing weights when available.

Internal volume20.944m³
Empty weight6.7615t
Operating weight19.223t
Hydrotest (water-full) weight27.664t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 2 m x 6 m, 2:1 heads. The inputs, in the units selected above:

InputValue
Inside diameter2,000.0 mm
Shell length tangent to tangent6.0000 m
Shell thickness16.000 mm
Head thickness16.000 mm
Head type2:1 ellipsoidal
Shell material density7,850.0 kg/m³
Allowance for nozzles, supports, internals15.000 %
Operating liquid density850.00 kg/m³
Operating liquid fill70.000 %

Applying the formula below gives:

ResultValue
Internal volume20.944 m³
Empty weight6.7615 t
Operating weight19.223 t
Hydrotest (water-full) weight27.664 t

Open this example in the calculator and change any input.

Formula

\(m_{shell} = \rho\pi(D_i + t_s)t_sL, \quad V = \frac{\pi D_i^2}{4}L + 2V_{head}, \quad m_h = m_e + \rho_wV\)

Variables

Symbol Meaning SI unit
\(D_i\) Inside diameter m
\(L\) Shell length tangent to tangent m
\(t_s\) Shell thickness m
\(t_h\) Head thickness m
\(\text{head}\) Head type -
\(\rho_s\) Shell material density kg/m³
\(k_a\) Allowance for nozzles, supports, internals -
\(\rho_l\) Operating liquid density kg/m³
\(\phi\) Operating liquid fill -
\(V\) Internal volume m³
\(m_e\) Empty weight kg
\(m_o\) Operating weight kg
\(m_h\) Hydrotest (water-full) weight kg

Method and standards

Vessel weights.

Where it is used

  • Foundation and support design.
  • Lifting and transport planning.

Common mistakes

  • Forgetting the hydrotest case.
  • Ignoring internals and insulation.

Assumptions and limits

  • Cylindrical vessel; uniform thicknesses.

References

  • Vessel weights from shell and head geometry
  • Megyesy
  • Pressure Vessel Handbook (Pressure Vessel Publishing)

Questions and answers

Why is hydrotest weight important?

Foundations, supports and lifting are often governed by the water-full weight, which can exceed the operating weight several times for gas vessels.

How accurate is the allowance?

Ten to twenty percent is typical at the concept stage; detailed weights come from the vessel drawing.

What do the defaults represent?

An illustrative 2 m diameter, 6 m tangent-to-tangent carbon steel vessel with 16 mm shell and 2:1 heads, 70 % full of a 850 kg/m³ liquid.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.