Worked example
Example: Illustrative 20 t on two lugs. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Weight lifted | 20.000 t |
| Load-bearing lugs | 2.0000 - |
| Sling angle from vertical | 30.000 ° |
| Dynamic load factor | 1.5000 - |
| Lug width at the hole | 160.00 mm |
| Lug thickness | 25.000 mm |
| Hole diameter | 52.000 mm |
| Hole centre to edge (in load direction) | 80.000 mm |
| Pin (shackle) diameter | 48.000 mm |
| Fillet weld leg | 12.000 mm |
| Total weld length | 600.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Load per lug (along the sling) | 169.86 kN |
| Net-section tension | 62.910 MPa |
| Tear-out shear | 62.910 MPa |
| Pin bearing | 141.55 MPa |
| Weld throat shear | 33.368 MPa |
Open this example in the calculator and change any input.
Formula
\(F = \frac{Wgk_d}{n\cos\theta}, \quad \sigma_t = \frac{F}{(b - d_h)t}, \quad \tau_{to} = \frac{F}{2(e - d_h/2)t}, \quad \sigma_b = \frac{F}{d_pt}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Weight lifted | kg |
| \(n\) | Load-bearing lugs | - |
| \(\theta\) | Sling angle from vertical | rad |
| \(k_d\) | Dynamic load factor | - |
| \(b\) | Lug width at the hole | m |
| \(t\) | Lug thickness | m |
| \(d_h\) | Hole diameter | m |
| \(e\) | Hole centre to edge (in load direction) | m |
| \(d_p\) | Pin (shackle) diameter | m |
| \(s\) | Fillet weld leg | m |
| \(L_w\) | Total weld length | m |
| \(F\) | Load per lug (along the sling) | N |
| \(\sigma_t\) | Net-section tension | Pa |
| \(\tau_{to}\) | Tear-out shear | Pa |
| \(\sigma_b\) | Pin bearing | Pa |
| \(\tau_w\) | Weld throat shear | Pa |
Method and standards
Lug checks.
Where it is used
- Vessel and skid lifting attachments.
- Temporary lifting points.
Common mistakes
- Assuming all four lugs share a load on a rigid lift.
- Ignoring sling angle.
Assumptions and limits
- In-plane load; pin close fit; uniform weld stress.
References
- Pin-connected plate lug checks
Questions and answers
Why include a dynamic factor?
Cranes jerk and loads swing; factors of 1.5–2 are common for lifting attachments.
Why does sling angle matter?
A sling at 30° from vertical carries 15 % more tension than a vertical one, and loads the lug sideways.
What do the defaults represent?
An illustrative 20 t vessel lifted on two lugs with slings at 30°, dynamic factor 1.5, 160 × 25 mm lugs with 52 mm holes, 80 mm edge, 48 mm pin and 12 mm welds 600 mm long.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Moss, Pressure Vessel Design Manual, 3rd ed. (Gulf, 2004), Bednar, Pressure Vessel Design Handbook, 2nd ed. (Van Nostrand Reinhold, 1986)